main counter = preset value
Automatic reset to zero when
main counter = preset value
Batch counter counts the number
of automatic repetitions of the
preset
Manual reset sets both counters
to zero.
Electrical reset sets only the
main counter to zero.
Count mode SUBTRACTING
with automatic reset and Batch
counter
Output (timed signal) active
when main counter = zero
Automatic reset to preset when
main counter = zero
Batch counter counts the number
of automatic repetitions of the
preset
Manual reset sets main counter
to preset value, batch counter to
zero
Electrical reset sets only the
main counter to the preset value
Count mode ADDING with
automatic reset and Total
counter
Output (timed signal) active
when main counter = preset
value
Automatic reset to zero when
main counter = preset value
Total counter counts all the count
pulses from the main counter
Manual Reset sets both counters
to zero
Electrical reset sets only the
main counter to zero
For the subtracting modes (SUB, SUBAR,
SUBBAT and SUBTOT), a „Reset" (via the
key or the input) resets the counter/the
time counter to a new preset value 2.
7.8.4.3 Mainmenu for configuration
Mainmenu for matching the input
pulses and display
Multiplication factor
Multiplication factor can be
programmed from 00.0001 to
99.9999.
The setting 00.0000 will not be
accepted
www.kuebler.com
Division factor
Division factor can be
programmed from 01.0000 to
99.9999.
The setting <01.0000 will not be
accepted
Decimal point setting
Decimal point (only optical
function)
0
0.0
0.00
0.000
0.0000
0.00000
Set value
Grafik
Set value can be programmed
from -999999 to 999999
A previously programmed
decimal point will be displayed
Display colour (for device 6.92x.x1x3.xx0)
Display colour
upper line
lower line
Display colour
upper line
lower line
7.8.4.4 Mainmenu for reset mode
Setting the reset mode
Manual reset (with red key) and
electrical reset (reset input)
No reset possible (red key and
reset input inhibited)
Only electrical reset possible
(reset input)
Only manual reset possible (red
key)
no decimal place
1 decimal place
2 decimal places
3 decimal places
4 decimal places
5 decimal places
red
red
red
green
Page 9