9
Connections
9.1
Signal and Control Inputs
N° Designation
1
AC: 24 VDC/80 mA
DC: U
connected
B
through
2
GND (0 VDC)
3
INP A
4
INP B
5
RESET
6
LOCK
7
GATE
8
MPI
9.2
Supply voltage and Outputs
9.2.1 Version with relays
N° Designation
9
n.c.
10 n.c.
11 Relay contact C
12 Relay contact N.O.
13 Relay contact N.C.
14 AC: 90..260 VAC N~
DC: 10..30 VDC
15 AC: 90..260 VAC L~
DC: GND (0 VDC)
www.kuebler.com
Function
Sensor supply
voltage
Common connection
Signal and Control
inputs
Signal input A
Signal input B
Reset input
Keypad lock
Gate input
User input
Function
-
Output
Supply voltage
Supply voltage
10 Technical Data
10.1
General Data
Display
LCD positive or negative,
backlit
2 x 6-digit
Digit height
upper line
lower line
special characters
Overload/
Blinking, 1 s
Underload
Counter loses no pulses up to
1 decade
Data retention
> 10 years, EEPROM
Operation
8 keys
10.2
Pulse counter
Count frequency max. 55 kHz (see section 13.
frequencies typ.)
Response time of the output:
Add/Sub
With automatic repeat
A/B ; (A-B)/A
10.3
Tacho/Frequency meter
Frequency range
0,01 Hz to 65 kHz (see
section 13. frequencies typ.)
Measuring
76.3 Hz Time interval
principle
(period measurement)
> 76.3 Hz Gate time
Gate time approx.13.1 ms
Measuring error
< 0.1% per channel
Response time of the output:
1-channel operation < 100 ms @ 40 kHz
< 350 ms @ 65 kHz
2-channel operation < 150 ms @ 40 kHz
< 600 ms @ 65 kHz
10.4
Timer
Seconds
Minutes
Hours
h.min.s
Min. time measurable
Measuring error
Response time of the output:
10.5
Signal and Control inputs
Polarity:
programmable NPN/PNP
for all inputs in common
Input resistance
5 k
Pulse shape
any
9 mm
7 mm
2 mm
< 13 ms
< 13 ms
< 34 ms
0.001 s ... 999 999 s
0.001 min ... 999 999 min
0.001 h .. 999 999 h
00h.00min.01s ...
99h.59min.59s
500µs
< 100 ppm
< 13 ms
Page 15