Gate control for Timing
Timing takes place when the
Gate input is not active.
Timing takes place when the
Gate input is active
User input
When the MPI input is activated
the display is "frozen" and
remains "frozen" until the MPI
input is deactivated.
Internally the preset timer
continues counting.
When the MPI input is activated
the current time value will be
adopted as the new preset value.
See also 7.9
When the MPI input is activated
the timer will be set to the value
specified in the parameter SEtPt.
See also 7.10
Lock input
When the Lock input is activated
the programming is inhibited.
When the Lock input is activated
the setting of the preset values is
inhibited.
When the Lock input is activated
the setting of the preset value
and the programming are both
inhibited.
7.8.6.2 Mainmenu for the output operations
Mainmenu for determining the
operation of the output
Count mode ADD
Output active when count status
> preset value
Reset to zero
Count mode SUBTRACT
Output active when
count status < 0
Reset to preset value
Page 12
Count mode ADDING with
automatic reset
Output (timed signal) active when
count status = preset value
Automatic reset to zero when
count status = preset value
Reset to zero
Count mode SUBTRACTING
with automatic reset
Output (timed signal) active when
count status = 0
Automatic reset to preset when
count status = 0
Reset to preset value
Count mode ADDING with
automatic reset and Batch
counter
Output (timed output) active
when main counter = preset
value
Automatic reset to zero when
main counter = preset value
Batch counter counts the number
of automatic repetitions of the
preset
Manual reset sets both counters
to zero
Electrical reset sets only the
main counter to zero
Count mode SUBTRACTING
with automatic reset and Batch
counter
Output (timed signal) active when
main counter = 0
Automatic reset to preset when
main counter = 0
Batch counter counts the number
of automatic repetitions of the
preset
Manual reset sets main counter
to preset value and batch counter
to zero
Electrical reset sets only the
main counter to preset value
Count mode ADDING with
automatic reset and Total
counter
Output (timed signal) active when
main counter = preset value
Automatic reset to zero when
main counter = preset value
Total counter counts all the count
pulses from the main counter
Manual Reset sets both counters
to zero
Electrical reset sets only the
main counter to zero