Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Display mode
Calculation and display of the
frequency / speed in 1/s
Calculation and display of the
frequency / speed in 1/min
Decimal point setting
Decimal point
(determines the resolution)
0
0.0
0.00
0.000
Moving average
Moving average calculated
AVG 2
AVG 5
AVG 10 over 10 measurements
AVG 20 over 20 measurements
Start delay
Programmable from 00.0 to
99.9 s
At the start of a measurement
the measurement results within
this time-period are ignored.
Waiting time
Waiting time Programmable from
00.1 to 99.9 s. This value
specifies how much time should
elapse, after the last valid edge,
before zero is to be displayed.
Display colour (for device 6.92x.x1x3.xx0)
Display colour
Upper line
Lower line
Display colour
Upper line
Lower line
7.8.5.3 Preset 1
See below 7.8.6.5
www.kuebler.com
no decimal place
1 decimal place
2 decimal places
3 decimal places
over 2 measurements
over 5 measurements
red
red
red
green

7.8.6 Timer

7.8.6.1 Mainmenu for the Signal and
Control inputs
Mainmenu for programming the
signal and control inputs
Input polarity
PNP: switching to Plus
for all inputs in common
nPn: switching to 0 V
for all inputs in common
Filter for the signal inputs Inp A and Inp B
for electronic control of the
signal inputs
for mechanical control of the
signal inputs(for control with
mechanical contacts)
Input mode Time measurement
Start: Edge to Inp A
Stop: Edge to Inp B
Start: 1. Edge to Inp B
Stop: 2. Edge to Inp B
Timing can only be controlled via
the Gate input
Inp A and Inp B: no function
The timer is reset by means of a
RESET (to zero when adding, to
preset when subtracting) and
then starts timing again.
Timing is stopped with adding
operations when preset is
reached. Timing is stopped with
subtracting operations when zero
is reached. A RESET during the
timing process also causes this
to stop.
Inp A and Inp B: no function.
Page 11

Publicidad

Tabla de contenido
loading

Tabla de contenido