MACHINE SETUP

INSTALLING BRUSH

1. Turn the main power switch to the (O) off position.
FOR SAFETY: Before servicing machine turn the
main power switch to the off position.
2. Raise the scrub head to the transport position by
stepping on the scrub head lift pedal (Figure 1).
3. Remove the brush idler plate from the brush base.
Turn the idler plate locking knob counter- clockwise
to remove (Figure 2).
4. Connect the slotted end of the brush to the drive
hub (Figure 3).
Nobles Speed Scrub 15 Battery (03- 11)
FIG. 1
FIG. 2
FIG. 3
5. Connect the idler plate to the brush and reinstall
the idler plate. Make sure the idler plate tabs
engage the brush base and that the locking knob is
secure (Figure 4).
NOTE: If storing the machine for an extended period,
raise the scrub head to the transport position to prevent
a flat spot developing on the brush.

FILLING SOLUTION TANK

1. Remove the solution tank from machine and carry
tank to water source (Figure 5).
2. Fill the solution tank with 2.5 gal / 9.5 l of clean water
(122F / 50C maximum temperature). Do not fill
beyond the "MAX" fill label (Figure 6). Partially fill if
unable to lift a full tank. A full tank weighs 26.5 lb.
FIG. 5
ATTENTION: When refilling solution tank always
empty the recovery tank.
ATTENTION: Do not use the recovery tank to fill
the solution tank. Dirt from the recovery tank may
cause damage to the solution pump.
3. Pour an approved low foaming cleaning detergent
into the solution tank according to the mixing
instructions on the bottle.
ATTENTION: Only use approved cleaning
detergents. Machine damage due to improper
detergent usage will void the manufacturer's
warranty.
ENGLISH
FIG. 4
FIG. 6