Water Supply And Drain Connections; Start-Up Procedure - Hoshizaki FM-1000ALE Manual De Instalación

Maquina de cubitos modular
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 22
ENGLISH
5. WATER SUPPLY AND DRAIN
CONNECTIONS
(For the U.K. only, the connections must be in
accordance with current requirements of the Model
Water Byelaws 1986 SI No. 1147)
* Only potable water should be used for the icemaker.
* Water supply pressure should be minimum 0.5 bar
and maximum 8 bar. If the pressure exceeds 8 bar,
use a proper pressure reducing valve. Do NOT throttle
back the supply tap.
* A plumbing permit and services of a licensed plumber
may be required in some areas.
* The icemaker drain is gravity flow, so ensure drain
pipe has an adequate pitch or fall.
* Water should drain into an open trap.
1) By means of a suitable spanner or wrench, tighten
the 1/2-3/4 nipple (accessory) into the Rc1/2 fitting
and the 3/4-3/4 nipple (accessory) into the Rc3/4
fitting on the rear of the icemaker as indicated.
P.T.F.E. tape and/or a suitable sealing compound
should be used to obtain a leak free joint.
Note: Jointing compounds should be approved and
suitable for potable water use.
2) Attach angled end of white flexible inlet hose
(accessory) to free end of 1/2-3/4 nipple ensuring
rubber sealing washer is correctly positioned. Hand
tighten sufficiently to provide leak free joint.
3) Attach the other end of inlet hose to the water tap
(Fig. 8), noting washer is correctly positioned before
hand tightening as above.
4) Attach grey flexible outlet hose (accessory) to free
end of 3/4-3/4 nipple as indicated, confirming fitment
of rubber washer before finally hand tightening the
joint. This pipe can be cut to length as necessary
to suit position of main drain.
5) The Storage Bin also has a drain which requires a
fitting and outlet pipe (not supplied). The two drains
must be separated to prevent a backflow from the
machine into the Bin.
1/2-3/4 Nipple
Inlet Hose
Outlet Hose

6. START-UP PROCEDURE

1) Check that the icemaker power supply cord is
disconnected.
2) Remove the Front Panel.
3) Move the Operation Switch to the "ON" position.
4) Open the water supply tap.
5) Connect the icemaker to the power supply and
energise.
Note: The compressor system should be set to run.
6) The icemaker display will illuminate in the "ICE"
mode.
7) The following will occur in sequence:
4
Water Supply
Inlet Rc1/2
Drain Outlet
Rc3/4
3/4-3/4 Nipple
Fig. 7
Water Supply Tap
Inlet Hose
Fig. 8
92U2CM20B0303

Publicidad