b
Be sure to view the monitor for adjustment
when the camera angle is adjusted.
Supply power to this unit, connect the monitor for adjust-
ment (e.g. a small LCD) to the monitor output jack, and
adjust the camera angle (turn off the power after view angle
adjustment for safety).
1. Loosen the 4 fixing screws of the lens cover to remove
the lens cover.
2. Connect the monitor for adjustment to the monitor out-
put jack.
Lens cover
Fixing screw x4
Note:
• The plug dimensions in the illustration below shall be
observed for the monitor for adjustment.
9 mm or less
Straight type
3. Repeat the steps (1) and (2) to adjust the camera
angle.
(1) Loosen the panning lock screw and rotate the cam-
era head horizontally to adjust panning.
(2) Loosen the tilting lock screw and rotate the camera
head vertically to adjust tilting.
(3) Tighten the panning lock screw and tilting lock
screw after camera angle adjustment.
Panning lock screw
Monitor output jack
(ø3.5 mm mini jack (monaural))
9 mm or less
L-type
Tilting lock screw
Important:
• After camera angle adjustment, the panning lock screw
and tilting lock screw shall be securely tightened.
Recommended tightening torque: 2.45 N·m
Notes:
• Use a hexagonal wrench with width across flats of 4
mm (locally procured) to loosen or tighten the panning
lock screw and tilting lock screw.
• Approximately 1 rotation of loosening the panning lock
screw and tilting lock screw allows camera angle
adjustment. Do not loosen the screws beyond necessi-
ty.
• The camera body shall be held when the panning lock
screw or tilting lock screw is loosened.
• Focus adjustment ( page 16) shall be performed
when panning and tilting adjustments are performed.
15