Lenze L-force E84DGDVB 4 Serie Instrucciones Para El Montaje página 85

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Settings with P2
(Lenze setting bold)
With P2 you set the motor setpoint speed as a percentage of the rated speed in
C00011 in 10 steps (preset speed setpoint). The preset setpoint is only activated
if the DI1 input is set in "Local mode".
P2
Description
Motor speed in percent of the rated speed
setting C00011
Settings with P3
(Lenze setting bold)
Use P3 to set the acceleration and deceleration time of the motor.
P3
Description
Acceleration and deceleration time of the
motor in seconds
Settings with P1
(Lenze setting bold)
During operation you can use P1 to steplessly set the motor speed as a
percentage of the rated speed in C00011 if no preset speed setpoint P2 is active
via DI1.
Remove cap in order to be able to set potentiometer P1.
Screw cap on again after the setting process, in order to ensure that the
ƒ
degree of protection of the inverter is provided.
P1
Description
Motor speed in percent of the rated speed
C00011
EDK84DGDVBxxx4 DE/EN/FR/ES/IT 8.3
DIP switch / potentiometer assignment 0
0
[%]
0
11 22 33 44 55 66 77 88
0
[s]
0.1
0.5
[%]
l
Settings
Setting
1
2
3
4
5
6
Setting
1
2
3
4
5
6
1
2
5
10 20 30 60 120
Setting
0
...
0
...
5
7
8
9
100
7
8
9
9
100
85