6
Commissioning
Commissioning via the diagnosis terminal
User menu
Paramete
Name
rs
C00011
Appl.: Reference
speed
C00012
Accel. time − main
setpoint
C00013
Decel. time − main
setpoint
C00015
VFC: V/f base
frequency
C00016
VFC: Vmin boost
C00022
Imax in motor mode Maximum current in motor mode for all
C00039/
Preset setpoint 1
1
(L_NSet_1 n−Fix)
C00039/
Fixed setpoint 2
2
C00051
MCTRL: Actual speed
value
C00053
DC−bus voltage
C00054
Motor current
C00061
Heatsink
temperature
C00087
Rated motor speed
C00099
Firmware version
C00105
Decel. time − quick
stop
C00120
Motor overload
threshold (I
C00137
Device status
C00166/
Mess. − status det.
3
error
C00173
Mains voltage
C00200
Firmware product
type
˘
96
Info
Setting the reference speed
FB L_NSet_1: Acceleration time of the ramp
generator for the main speed setpoint
FB L_NSet_1: Deceleration time of the ramp
generator for the main speed setpoint
V/f base frequency for VFCplus motor control
Boost of the V/f voltage characteristic within
the range of low speed or frequency values
for the VFCplus motor control.
motor control modes
FB L_NSet_1: Fixed speed setpoints (JOG
values) for the setpoint generator
Fixed setpoint 1
Fixed setpoint 2
Actual speed value of the motor shaft
Actual DC−bus voltage
Current motor current/output current of the
inverter
Current heatsink temperature
This value can be obtained from the motor
nameplate. After the motor to be used has
been selected from the motor catalogue, the
suitable value can be entered automatically.
Firmware version of the device as string
The set deceleration time determines the
ramp slope at quick stop
Operating threshold for the error message
2
xt)
"OC6: Motor overload (I
Current device state
Textual message of the currently pending
error
Selection of the mains voltage for operating
the device.
Read only
2
xt)"
l
EDK84DGDVBxxx4 DE/EN/FR/ES/IT 8.3
Lenze setting
1500 rpm
2.0 s
2.0 s
50 Hz
2.6 %
5.8 A
40.0 %
60.0 %
˘
˘
˘
˘
1320 rpm
˘
5.0 s
100 %
˘
˘
0: "3ph 400V"
˘