Paragraph 8 – Timed Dosage (Frequency signal input "TRIGGER" not activated)
Programming
+
PROG
Config.
Config.
Funct.
Funct.
Timer
Q.ty
100
ml
Delay
00.00.00
Interval
00.00.00
Trig.Mode
Disabled
PausMode
Restart
Function mode
Timer
Alarms and statuses
Lev = Level Alarm
Flw = Flow Alarm
EM00136320
The pump doses a programmed quantity in mL. It is possible to set a
delay time (Delay) for the pump start up and an interval between
subsequent dosages (Interval) as shown on the diagram:
The
(days.hours.minutes)
The Pause input can be programmed in three different modes:
The dosage frequency can be modified during the pump operation by
pressing
PausMode
Restart
PausMode
Pasue
PausMode
Freeze
Display during operation
empty = pump in stating
Stop = pump in stop
Paus = pump in pause
Delay
Interv.
Delay
and
Interv.
1. Freeze Time: with the pause activated, the system stops the
current time count and restarts the count when the pause is
deactivated
2. Pause Dosing: with the pause activated, the system
continues to count the time and stops the dosage.
3. Restart Timer: with the pause activated, the system stops the
dosage and when the pause is deactivated the count restarts
from the beginning.
+
simultaneously.
Tempo
100ml
Pump status
rev.2.0
EN
Operation
Quantity
times
are
in
Set dosing quantity
(display during the
dosing)
dd.hh.mm
format