Fault
Condensation forms on the
dispenser unit.
Ice cubes have an unpleasant
odor/flavor.
Ice maker is not producing any ice.
Ice is not dispensed.
The dispenser light does not
function.
The ice maker is not producing
enough ice or the ice cubes are
g
misshapen.
24
Possible cause
The ice maker is switched off
(see Switching off the ice maker").
The condensation heater does not
function.
Ice which is stored for a long time may
absorb odors which impair their taste.
The ice cube container is dirty.
Unsealed packages in the freezer
transfer odor/flavor particles to the ice
cubes.
Clean the inside of the appliance.
The ice cube container is in the false
position.
The water pressure is too low.
The freezer compartment temperature
is too high.
A wrong water valve has been
installed.
The agitation function in the ice cube
container is switch off. The filling level
sensor is blocked.
Two ice cubes can by chance be
attached to each other. These ice
cubes, when joined together, can block
the ice chute so that no further ice can
be dispensed.
The bulb is defective.
The water pressure is too low.
The freezer compartment temperature
is too low.
Change the water filter.
Remedial action
You have to activate the condensation heater.
- Switch on the ice maker.
- Simultaneously hold down the LOCK OUT and the
AGITATION buttons for 3 seconds.
The WATER light and the ICE CUBE light flash twice.
The ice maker is switch off and the condensation heater
works.
To re activate the condensation heater:
- Simultaneously hold down the LOCK OUT and the
AGITATION buttons for 3 seconds.
The WATER light and the ICE CUBE light flash once.
Dispose of old ice cubes. Use the ice maker more
frequently.
Empty and wash out the ice cube container.
Check whether the frozen food has been packed
in airtight containers.
See section on Odors".
Reinsert the container and slide it backwards to the end
position (see section Variable interior design").
Check water pressure. The water pressure must be
between 25 and 120 p.s.i. (1.72 8.25 bar).
Check temperature of the freezer compartment.
If required, lower the temperature.
Self tapping valves and 3/16 inch (4.76 mm) saddle
valves reduce the water pressure and may eventually
block the pipe.
The manufacturer is not liable for damage to
property due to an incorrect installation or water
connection.
Pull out and empty the ice cube container. Remove the
ice on the sensor.
Open the door.
Remove all of the ice out of the ice chute.
Change the bulb (see Changing the bulb").
Check water pressure. The water pressure must be
between 25 and 120 p.s.i. (1.72 8.25 bar).
Check temperature of the freezer compartment.
If required increase the temperature.
Instructions for changing the water filter can be found
in the section Water filter".