Fault
Ice is forming in the supply hose to
the ice maker.
Water is flowing out of the
appliance.
pp
è Close shut off valve immediately.
Changing the
bulb
d
WARNING
To avoid electrical shock which
can cause severe personal injury
or death, disconnect power to
appliance before making repairs.
After making repairs, reconnect
power.
q
Switch off the appliance with
the POWER button!
CAUTION
Never touch a halogen bulb with
bare fingers. When inserting
a glass halogen bulb, always hold
with a soft cloth.
We recommend that a service
technician changes the bulb.
Possible cause
The water pressure is too low.
The freezer compartment temperature
is too low.
The water pipe in the appliance is
defective.
The water pressure is too low.
A wrong water valve has been
installed.

Halogen bulbs above

Halogen bulb type:
20 W/12 V/bulb holder G4
d
q
Release and remove the cover.
q
Pull out the defective halogen
bulb.
q
Insert a new halogen bulb.
Touch the halogen bulb with
a soft cloth only.
Remedial action
Check water pressure. The water pressure must be
between 25 and 120 p.s.i. (1.72 8.25 bar).
Check temperature of the freezer compartment.
If required increase the temperature.
Call customer service immediately.
The valve may leak if the water pressure is too low.
The water pressure must be between 25 and 120 p.s.i.
(1.72 8.25 bar).
Self tapping valves and 3/16 inch (4.76 mm) saddle
valves reduce the water pressure and may eventually
block the pipe.
The manufacturer is not liable for damage to
property due to an incorrect installation or water
connection.
q
Attach the cover to the clip and
lock into position.
25