Parts Identification; Operating Your Dehumidifier; Set Unit Upright; Set Up Drain Hose - Dri-Eaz LGR 2800i El Manual Del Propietario

Ocultar thumbs Ver también para LGR 2800i:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PARTS IDENTIFICATION

FIG. C: POWER AND PUMP
ATTACHMENT POINTS
AA batiery companntent Provides
power to HygroTrac .Lkireless
transmitter 1.% lien unit is 1101 plugged in.

OPERATING YOUR DEHUMIDIFIER

Set unit upright

NOTICE:
If you transport an i-Series dehumidifier in a
horizontal position. set it upright and let it stand for at
least 30 minutes before you turn it on. When the
machine is horizontal, the oil from the compressor flows
into the refrigerant coils reducing the ability of the
dehumidifier to function. Letting the unit stand upright for
141 Kirrierkarnack Rd. Park Ridge, NJ 07656 Tel
Molded pocket
For cord storage.
Humid air inlet
(both sides).
Process (dehumidified)
air outlet. May be used
with standard 12" rigid
or lay flat ducting.
Bottom aback
poly et hylene housing.
Remov e two bolls to
retno% e pump for cleaning.
Air Marketing Group
201-782-1782 Fax. 201-782-1783 Web www amgair corn Email: info@amgair corn
Lower back panel_ Remove
this panel to access the
pump for set-% icing
FIG. D: PUMP ACCESS PANEL
Lower back panel. Remove the
live retaining screws to remove
pump For cleaning.
30 minutes allows the oil to flow back into the
coMpressor.

Set up drain hose

The i-Series condensate pump connects to a plastic
hose that is located in the pocket on the back
drainage
of the unit. This hose is equipped with a quick-connect
fitting for quick attachment to the provided 40-ft. drain
hose. Unwrap the entire hose and place the unattached
end in a sink, drain, bucket or outside — anywhere that
water can drain out safely. If you use a bucket or other
Rugged rotomolded
housing resists dents
and scratches and is
ea
sy to maintai
n.

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Lgr 3500iF410F411

Tabla de contenido