17.3 Causes and rectification of faults

Error
The selected program
will not start.
The turntable turns
jerkily.
Food is not sufficiently
defrosted, warmed up
or cooked after preset
time has elapsed.
The device functions
but the cooking
chamber lighting does
not work.
Abnormal noises can
be heard during
operation of
microwave.
The time in the display
field is not correct.
caso MCDG 25 Master black
Please note
► If error messages continue to appear after an extended
waiting period and restarting the device, then the device will
need to be sent to Customer Service to be inspected.
The following table assists in localizing and rectifying minor
faults.
Possible cause
Device door is not closed
Power plug is not plugged in
Fuse is not activated
Dirt between the turntable and
the base of cooking camber
Dirt on rolling ring
Cooking vessel too large
Incorrectly selected time or
power level
Defective cooking chamber light.
Food is covered with aluminium
foil
The cookware contains metal
and sparks are being created
within the cooking chamber
Power failure
Attention
► If you are unable to solve the problem with the steps shown
above, please contact Customer Service.
Action
► Close device door
► Plug in mains plug!
► Activate fuse
► Remove dirt
► Use different cooking
vessel
► Re-set time and power
level
► Repeat process
► Have Service dept
repair cooking chamber
light.
► Remove aluminium foil
► Observe information on
cookware!
► Re-set time
88