Programming
The system is capable of storing four independent
pattern programs. Programs are stored in memory
positions A through D. Familiarize yourself with the
controls and indicators provided on the control unit
before attempting to create a pattern program.
NOTE: The system uses a directed programming
approach. Observe the following restrictions and
conditions when creating a pattern program.
S
The programming sequence must be followed in
the order given. Changes to values set in previous
steps cannot be made until programming is
complete.
S
Each step must be completed before going to the
next step.

Controls and Indicators

Location of Controls and Indicators
1. System power switch
2. Enter key
3. Display
4. Up/down arrow keys
5. Gun test/purge key
Manual 340289C
02
66-TEMPUS-MA-01
9
8
A
7
B
C
D
6
5
6. Gun test/purge light
7. Lights for program memories
8. System power light
9. Trigger light (input)
10. Gun light (output)
S
The system does not allow the entry of any
out-of-range values for end gap and bead
length.
S
If system power is interupted during the
programming sequence, the system will return
to the same point in the sequence when
system power is restored.
S
If an incorrect value is registered (by pressing
the enter key) while creating a pattern
program, you must complete the programming
sequence and then restart the sequence in
order to make changes. Refer to Operation for
information on editing an existing program.
11
10
12
13
14
15
4
3
11. Gun-trigger offset (GTO) light
12. Timer calibration light
13. End gap light
14. Bead length light
15. Product length light
10
1
2
6601003