______________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
10. LIST OF VARIABLE FUNCTIONS (0 ... 99)
FUNCTION
Applied motor force setting during opening (TRIAC) 00 =100 %
0
Obstacle detection sensitivity during opening
1
Warning light mode ON/OFF (1 =ON : 0 = OFF)
2
Obstacle Detection Action (if limit switches are available) 0 =
STOP
3
1 = STOP/REVERSES
2 = STOP/ REVERSES for 2 secs../STOP/CLOSE
Radio channel CH1 command (step-by-step)
0 = TO OPEN
1 = TO OPEN/CLOSE
4
2 = TO OPEN/CLOSE
3 = TO OPEN/STOP/CLOSE/STOP
OPEN Command in terminal strip
5
0 = TO OPEN
1 = same as step-by-step Radio channel 1 (FUNCTION 4)
SAFETY during Opening
6
0 = disabled
1 = TO STOP
2 = TO STOP and CLOSE
SAFETY during Closing
0 = disabled
7
1 = TO STOP
2 = TO STOP and OPEN
SAFETY during Closing and Opening (photocell)
0 = disabled
1 = TO STOP
8
2 = TO STOP and OPEN (upon photocell resetting).
3 = TO STOP and CLOSE (after 3 secs) (upon photocell resetting).
4 = STOP and OPEN after 1.5 secs (without photocell resetting)
Maximum Opening/Closing Time
9
AUTOMATIC CLOSING Dwell Time
10
CLOSING Limit Switch
0 = disabled
11
1 = enabled
OPENING Limit Switch
12
0 = disabled
1 = enabled
Pre-Opening Flashing Time
13
Pre-Closing Flashing Time
14
Partial opening Time
20
Safety Self-Test (photocells) at start of manoeuvre
41
0 = OFF
1 = ON
Applied motor force control during closing (TRIAC) 00 =100 %
69
Obstacle Detection Sensitivity during Closing
70
99
Input Status Check
PRASTEL S.r.l. Via del Vetraio, 7 40138 Bologna Italy - Tel. +39-051-6023311 Fax +39-051-538460
E-mail: info@prastel.com - Web site: http://www.prastel.com
EURO/1MF-2 vers. 1 morsettiera.doc- 16/06/99
DESCRIPTION
V
26
Min/Max
50 ÷ 100%
0 ÷ 10
0 ÷ 1
0 ÷2
0 ÷ 3
5
1
0 ÷ 1
N.O.
1
6
0 ÷ 2
N.C.
1
7
0 ÷ 2
N.C.
8
1
N.C.
0 ÷ 4
1 ÷ 99 sec.
0 ÷ 99 sec.
0
11
0 ÷ 1
N.C.
0
12
0 ÷ 1
N.C.
0 ÷ 10 sec.
0 ÷ 10 sec.
20
1
3 ÷ 60 sec.
N.O.
0 ÷ 1
50 ÷ 100%
0 ÷ 10
All inputs on
the control
R
terminal strip
Pre-set
75
5
1
0
1
0
0
0
0
30 sec.
3 sec.
1
1
1
3
5 sec.
0
75
5
5