______________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________
11. OPERATION (continues):
OPERATOR IN ATTENDANCE MANOEUVRE
Press the STOP button (opening of the NC contact on input 9 - page 12). The unit can now perform the so-called
"OPERATOR IN ATTENDANCE" manoeuvre, i.e. the automatic access can be opened or closed by means of two
NO external contacts (terminals 1-4, 1-5 of the control terminal strip). These commands are given by the operator
keeping the NO contacts closed.
Note:
In performing this manoeuvre, the status of the safeties and of the obstacle detection is disregarded by
the unit.
Note:
The Stop contact should always be closed to allow the automatic operating mode of the unit.
OPENING MANOEUVRE
Send a radio command via channel 1 or an "OPEN" command (via terminals 1 & 5) or a "PARTIAL OPENING"
command (via terminals 1 -20).
The warning light will start flashing before the access opens for a time as set via function "13".
The unit performs the TRIAC and the opening manoeuvre safeties self-test (only if terminal 41 is connected and
"FUNCTION 41" is set to "1").
The motor is powered for 1.5 sec at a 100% pick-up force, after which the applied motor force drops to that set via
function "0".
Note: When the manual opening contact is kept closed (terminals 1 and 5), the unit does not carry out any
closing operations. The function is active only if the limit switches are available.
CLOSING MANOEUVRE
Closing may occur automatically after the time set via function "10" or via radio commands (radio channel 1 and with
function "4" set to 1, 2 or 3), via the "OPEN" command with "FUNCTION 5" set to 1, or via the CLOSE command
(terminals 1 & 4).
The warning light will start flashing before the access closes for a time as set via function "14".
The unit performs the TRIAC and the closing manoeuvre safeties self-test (only if terminal 41 is connected and
"FUNCTION 41" is set to "1").
The motor is powered for 1.5 sec at a 100% pick-up force, after which the applied motor force drops to that set via
function "69".
PARTIAL OPENING MANOEUVRE
This manoeuvre is performed by a NO contact wired up between terminals 1 and 20 of the control terminal strip.
The unit behaves as during the opening manoeuvre; the manoeuvre ceases upon the time set via function "20"
elapsing.
Closing may occur automatically after the time set via function "10" or via radio commands (channel 1, and with
function "4" set to 1, 2 or 3), via the "OPEN" command with "FUNCTION 5" set to 1, or via the CLOSE command
(terminals 1 & 4).
PRASTEL S.r.l. Via del Vetraio, 7 40138 Bologna Italy - Tel. +39-051-6023311 Fax +39-051-538460
E-mail: info@prastel.com - Web site: http://www.prastel.com
EURO/1MF-2 vers. 1 morsettiera.doc- 16/06/99
29
M E M B E R
O F

Publicidad

Tabla de contenido
loading

Tabla de contenido