3 8 0 /3 /5 0 H z C O N N E C T IO N S
V /A
B L U E
B L A C K
Q U O IT
R E D
ADVISE: Heating Pump must not work if the cleaning pump it is not working. Avoid installing delays that could lead to
these situations. Do not modify the motor protections. In case of any doubt contact the installer.
All local and national electricity codes concerning the protection of defects in electric power lines should be
respected at all times during the electrical installation.
Verify the torque of all electrical connections.
The electrical resistance between the ground and any electric terminal will be verified to be over 1 megaohm.
In the case of fluctuations in the power supply, a power supply stabilising system is recommended in order to
protect the equipment.
WARNING: DO NOT modify the compressor protections. Do not hesitate contact the distributor if it is needed
G R O U N D
G R O U N D
1
N E U T R A L
2
R
3
S
4
T
2 2 0 /2 /5 0 H z C O N N E C T IO N S
V /A
B L U E
R E D
13
ENGLISH
G R O U N D
2 2 0 V
.