8: Low pressure switch
9: Door switch with fan stop only
10: Direct/reverse
11: Light sensor
12: Activation of the AUX output
13: Door switch with compressor and fans off and light not managed
14: Door switch with fans only off and light not managed
A5
Digital input 2 confi guration
As for A4
A6
Stop compressor from external alarm
A7
External alarm detection delay
A8
Enable alarms 'Ed1' and 'Ed2'
0: Alarm signals Ed1 and Ed2 enabled
1: Alarm signals Ed1 and Ed2 disabled
A9
Digital input 3 confi guration
As for A4
Ado
Light management mode with door switch
0: With normal algorithm
1: With extended algorithm
Ac
High condenser temperature alarm
AE
High condenser temperature alarm differential
Acd
High condenser temperature alarm delay
AF
Light sensor OFF time
ALF
Antifreeze alarm threshold
AdF
Antifreeze alarm delay
Simbol
Code
Parameter
F0
Fan management
0: Fans always on
1: Fans controlled according to the temperature difference between the virtual
control probe and the evaporator temperature
2: Fans controlled according to the evaporator temperature
F1
Fan start temperature
F2
Fan OFF with compressor OFF
0: Fans always on
1: Fans off with compressor off
F3
Fans in defrost
0: Fans operate during defrosts
1: Fans do not operate during defrosts
Fd
Fan OFF after dripping
F4
Condenser fan stop temperature
F5
Condenser fan start differential
Simbol
Code
Parameter
H0
Serial address
H1
Function of relay 4
0: Alarm output usually energised
1: Alarm output usually de-energised
2. Auxiliary output
3: Light output
4: Auxiliary evaporator defrost output
5: Pump down valve output
6: Condenser fan output
7: Delayed compressor output
8: Auxiliary output with deactivation when OFF
9: Light output with deactivation when OFF
10: No function associated with the output
11: Reverse output in control with dead band
12: Second compressor step output
13: Second compressor step output with rotation
H2
Disable keypad/IR
0
1
2
3
4
5
6
"•" = Disabled
•
•
•
•
•
•
•
•
•
•
•
•
•
Keypad function
AD
-
AD
min
AD
min
AD
fl ag
AD
-
AD
fl ag
AD
°C/°F
AD
°C/°F
AD
min
AD
s
AD
°C/°F
AD
min
AD
U.O.M.
D
fl ag
D
°C/°F
D
fl ag
D
fl ag
D
min
AD
°C/°F
AD
°C/°F
AD
U.O.M.
AD
-
AD
fl ag
AD
fl ag
•
•
•
•
•
•
9
C
0
14
0
C
0
100
0
C
0
250
0
C
0
1
0
C
0
14
0
C
0
1
0
C
0.0
200
70.0
C
0.1
20
10
C
0
250
0
C
0
250
0
C
-50
200
-5.0
C
0
15
1
Type
Min
Max
Def.
C
0
2
0
F
-50
200
5.0
C
0
1
1
C
0
1
1
F
0
15
1
C
-50
200
40
C
0.1
20
5.0
Type
Min
Max
Def.
C
0
207
1
C
0
13
1
C
1
6
1
+050004105 rel. 2.2 del 26.09.07