Intended use 
FiltoSmart 100/200/300 , FiltoSmart Thermo 
100/200/300,  referred to as "unit", may only be used 
as specified in the following: 
• FiltoSmart: Water filtering and recirculation.
• FiltoSmart Thermo: Water heating, filtering and re‐
circulation. 
• For operation with freshwater or saltwater.
• Operation under observance of the technical data.
The following restrictions apply to the unit: 
• Only use indoors and for aquaristic purposes in the
home (not for commercial use). 
• Only operate with water at a water temperature of
+39 °F to +95 °F.
Function description 
 C 
Drawn in by a pump in the unit head, the water flows 
through  two  filter  chambers  arranged  next  to  each 
other. Then the water flows back into the aquarium via 
the flow‐out pipe or water distributor. 
Foam  filters  with  different  pore  densities,  and  acti‐
vated carbon/ceramic substrate serve as filter media. 
In units with heater, the water is heated during its pas‐
sage through the filter system. 
Retrofitting 
FiltoSmart 100/200/300  can be retrofitted with OASE 
HeatUp (following table). 
 The  retrofit  set  ThermoFit  (following  order  num‐
bers) is required for installation. 
FiltoSmart 
25 
50 
100 
150 
200 
300 
: Suitable : Particularly recommended
 
• 48507 ThermoFit FiltoSmart 100
• 48532 ThermoFit FiltoSmart 200
• 48567 ThermoFit FiltoSmart 300
 
ACCESSING THE UNIT 
N O T E  
The following applies to all units with heater: 
 Adhere to the rules for careful handling. (→ Careful
handling of the heater) 
100 
200 
300 
 
 
 
 
 
 
 
 
 
 
 
— 
 
 
– 
 
– 
– 
Careful handling of the heater 
C A U T I O N  
Hot surface! 
Risk of burns when touching the glass bulb. 
• Unplug the heater and allow it to cool down be‐
fore removing it from the water.
C A U T I O N  
Risk of breaking the glass! 
The glass bulb of the heater can break and cause cuts. 
• Take care when handling the heater.
• Allow the heater to cool down first. Do not 
immerse it in cold water or pour cold water over it.
• Take care of glass fragility when installing the
heater in the adapter or the opposite operation
Removing the heater 
The heater has to be removed for cleaning and mainte‐
nance, and for removing the unit head. 
How to proceed: 
 D 
 
1. Unscrew the holding ring together with the heater
counter‐clockwise. 
Fitting the heater 
How to proceed: 
 E 
1. Screw  the  holding  ring  with  heater  clockwise  into 
the threaded hole. 
– To exchange the heater: Moisten the glass bulb
with water and push the heater into the holding
ring as far as it goes. 
Removing the connection unit 
The heater has to be removed for cleaning and mainte‐
nance, and for removing the unit head when hoses are 
connected. 
 
How to proceed: 
 F 
1. Turn  the  bayonet  closure  in  the  direction  "UN‐
LOCK". 
2. Remove the connection unit. 
 
‐  EN  ‐ 