ACCESSING THE UNIT

N O T E
The following applies to all units with heater:
• Adhere to the rules for careful handling. (→ Careful
handling of the heater)
Careful handling of the heater
C A U T I O N
Hot surface!
Risk of burns when touching the glass bulb.
• Switch off the heater and allow it to cool down be-
fore removing it from the water.
C A U T I O N
Risk of breaking the glass!
The glass bulb of the heater can break and cause cuts.
• Take care when handling the heater.
• Allow the heater to cool down first. Do not immerse
it in cold water or pour cold water over it.
Removing the heater
The heater has to be removed for cleaning and mainte-
nance, and for removing the unit head.
How to proceed:
 D
1. Unscrew the holding ring together with the heater
counter-clockwise.
Fitting the heater
How to proceed:
 E
1. Screw the holding ring with heater clockwise into
the threaded hole.
– To exchange the heater: Moisten the glass bulb
with water and push the heater into the holding
ring as far as it goes.
Removing the connection unit
The heater has to be removed for cleaning and mainte-
nance, and for removing the unit head when hoses are
connected.
How to proceed:
 F
1. Turn the bayonet closure in the direction "UN-
LOCK".
2. Remove the connection unit.
20
Fitting the connection unit
How to proceed:
 G
1. Fit the connection unit.
– Ensure that the ridges on the connection unit are
correctly aligned to the recesses on the unit
head.
2. Turn the bayonet closure in the direction "LOCK".
Dismantling the unit head
It has to be removed for cleaning and maintenance
and for changing the filter media.
Prerequisite:
• The heater has been removed. (→ Removing the
heater)
• The connection unit has been removed. (→ Remo-
ving the connection unit)
How to proceed:
 H
1. Undo the fasteners.
2. Remove the unit head.
Fitting the unit head
How to proceed:
 I
1. Check that the seal on the unit head is correctly po-
sitioned.
– Clean the seal, replace it if damaged.
2. Ensure that the vent hose is in place and is pointing
upwards.
3. Fit the unit head onto the container.
4. Hinge all fasteners up and lock them in place.
Fitting the retrofit set
N O T E
The following applies to all units with heater:
• Adhere to the rules for careful handling. (→ Careful
handling of the heater)
Prerequisite
• The unit head is removed. (→ Dismantling the unit
head)
How to proceed:
• Steps 1 and 2 do not apply to FiltoSmart 100.
 K
1. Take out a separating plate.
2. Remove any residue from the removal of the sepa-
rating plate.
3. Push the stand into the heater tube.
4. Fit the heater tube with tube holder into the recess
in the bottom of the container.
5. Insert the separating plate again.