Table 23: leds on control unit keys
Led 1
Off
On
Flashing
Led L2
Off
On
Flashing
Led L3
Off
On
Flashing
Led L4
Off
On
Flashing
Led L5
Off
On
Lampeggia
Led L6
Off
On
Flashing
Led L7
Off
On
Flashing
Led L8
Off
On
Flashing
7.8) Accessories
The following optional accessories are available for RUN:
• SMXI or SMXIS: Radio receiver at 433.92MHz with digital Rolling
Code encoding.
• ONEXI: Radio receiver at 433.92MHz with digital Rolling Code
encoding; equipped with Modo III to send 15 types of command
to control unit
7.8.1) Remote programming unit
More specifically, connector BusT4 (see figure 30) enables connec-
tion of the remote programming unit Oview which enables complete
and rapid management of installation, maintenance and trouble-
shooting of any malfunctions.
To access the connector, remote the membrane as shown in figure
31. The remote programming unit can be placed at a distance from
the control unit, with up to 100m of cable; it can be connected
simultaneously to up to 16 and can remain connected during normal
operation of RUN; in this case a specific "user" menu enables deliv-
ery of commands to the control unit.
If a OXI (o OXIT) type radio receiver is inserted in the control unit, the
remote programming unit enables access to the parameters of the
memorised transmitters.
These functions require a 4-core connection cable (BusT4).
The RUN control unit firmware can also be updated. Further informa-
tion is available in the Oview programmer instruction manual.
Description
During normal operation indicates "Automatic closing" not active
During normal operation indicates "Automatic closing" active
• Function programming in progress
• If Flashing with L2 indicates need for device self-learning phase (see paragraph "4.3 Device self-learning").
Description
During normal operation indicates "Reclose after Photo" not active
During normal operation indicates "Reclose after Photo" active
• Function programming in progress.
• If flashing with L1, indicates need for device self-learning phase (see paragraph "4.3 Device self-learning")
Description
During normal operation indicates "Always close" not active.
During normal operation indicates "Always close" active.
• Function programming in progress.
• If flashing with L4 indicates need for device self-learning phase (see paragraph "4.3 Device self-learning")
Description
During normal operation the device indicates "Stand-by" not active.
During normal operation the device indicates "Stand-by" active.
• Function programming in progress.
• If flashing with L3 indicates need for leaf length self-learning phase (refer to Paragraph "4.4 Leaf length
Self-learning").
Description
During normal operation indicates "Thrust" not active.
During normal operation indicates "Thrust" active.
Function programming in progress.
Description
During normal operation indicates "Pre-flash" not active.
During normal operation indicates "Pre-flash" active.
Function programming in progress
Description
During normal operation indicates that the CLOSE input activates a close manoeuvre
During normal operation indicates that the CLOSE input activates a partial opening manoeuvre.
Function programming in progress
Description
During normal operation indicates that RUN is configured as Master
During normal operation indicates that RUN is configured as Slave
Function programming in progress
• OperaView; Remote programming unit.
Consult the Nice S.p.a. product catalogue for the complete and
updated list of accessories.
IMPORTANT – For further details on all functions of the NiceOpera
system and interdependency of the various devices in the system,
refer to the general manual "NiceOpera System Book", also available
on the Internet site www.niceforyou.com.
30
31
23

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Run1800pRun2500Run2500p

Tabla de contenido