INSTALLATION OF DRIVE COVER
The drive cover is fixed at the side with 4 screws. Before positioning the
drive cover the plastic thread inserts must be pushed into the door
strengthening rails at the appropriate height. Before the cover is pushed
on from the front, the screws should be given another turn.
EXCHANGING BULBS
Warning: Isolate drive from mains.
The plastic cover is screwed on at the side and after removing 2 screws
on the left and 2 on the right it can be pulled downwards.
The transparent light cover underneath is fixed with 4 Phillips screws
(PZ1) and after they have been removed it can be lifted off. The bulb is
seated in a screw holder, type E14/25W.
Never use stronger bulbs. After exchanging the bulb reassembly takes
place in the reverse order. Pay attention to the sealing fitting around the
transparent light cover, which must be properly positioned.
Bulbs are not subject to guarantee claims.
LATCH / UNLATCH DRIVE
If the drive is unlatched the door can be opened or closed by hand..
If the drive is locked the door can only be operated with the
drive (Fig. 11).
Unlatching:
In a recess at the back of the plastic cover is an unlatching key. Take it
out and push it into the marked opening which is also on the back of the
drive. By turning it clockwise through about 180° the drive is unlatched.
Latching:
With the unlatching key pushed in turn it clockwise until you feel a solid
resistance. Then move the door a little by hand until you hear it click or
you can establish that the door is latched again.
If 2 drives are mounted on the door both of them must be unlatched and
latched.
If the garage has no external access it is necessary to mount an
external unlatching system for the situation when the drive is without
power.
CHECKS
Carry out a basic functional test on the drive and accessories. Hand
over to the customer the page entitled "User Information", demonstrate
the proper operation and use of the drive as well as showing them any
potential hazards.
MAINTENANCE
The following steps should be carried out at least every 6 months:
• Checking the regulation of the motor torque.
• Check the rollers and guide rails on the door. Carry out cleaning and
lubrication as necessary.
• Functional check of the interlock release system.
• Functional check of the safety equipment.
REPAIRS
The authorized Service Centres are responsible for repair work.
709302-GB - 05.2004
TECHNICAL DATA
Model
Supply voltage
Frequency
Nominal power
Max. power
Max. torque
Capacitor
Thermal protection
Motor speed
Temperature
Operating frequency, cycles/hr
Weight
Type of protection
Max. door width (m), 1 motor
Max. door height (m), 1 motor
Max. door area (m
Max. door width (m), 2 motors
Max. door height (m), 2 motors
Max. door area (m
The undersigned, hereby declare that the equipment specified, and all accessories,
conforms to the Directives and Standards stated.
Model: ..................................................................................................................BAS300
EN55014, EN61000-3, EN61000-4, ETS 300 683, EN 300 220-3, EN60335-1, and
EN60335-2-95
✓ 89/336/EEC
✓ 73/23/EEC
✓ 1999/5/EC
A power door operator, in combination with a door must be installed and maintained
according to all the Manufacturer's instructions, to meet the provisions of Machinery
Directive, 89/392/EEC.
B. P. Kelkhoff
Manager, Regulatory Affairs
THE CHAMBERLAIN GROUP, INC.
Elmhurst, IL 60126
USA
November, 2003
© Chamberlain GmbH, 2004
BAS300
230Volt
50Hz
250W
400W
350Nm
10µF
140
O
C
1400 rpm
-20 to + 55
20
approx. 9kg
IP44
3
3
2
), 1 motor
8
5
3
2
), 2 motor
14
D e c l a r a t i o n o f C o n f o r m i t y
D e c l a r a t i o n o f I n c o r p o r a t i o n
Manager, Reg. Affairs
O
C
Barbara P. Kelkhoff