Oase FILTOCLEAR 800 Garantia, Instructivo De Seguridad Y De Operaciones página 11

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

P
= 2,9 psi
max
(0,2 bar)
max.
6,5 feet
min
6,5
feet
¾"
1''
1 ¼''
1 ½''
For hoses that are longer than 13 feet, please always use hoses
that correspond to the upper value of the scale.
In order to avoid pressure loss, cut the spiral stepped hose adapter
at the relevant points for each hose.
Avoid unnecessary corners and bends which contribute to further
pressure loss.
Installing and connecting the Filtoclear
pressure filter
Installing the Filtoclear pressure filter
Choose a suitable location for the pressure filter. Please note the
installation guidelines regarding the clear water guarantee as well
as the following guidelines:
– Install the Filtoclear pressure filter with integrated UVC so that
it is safe from flooding. Secure your Filtoclear so that it will not
fall into the pond. It should be placed at least 6,5 feet from the
edge of the pond.
– Place the filter on a firm and level base, e.g. on a slab. The filter
can also be buried up to the lip of the filter canister.
– Please ensure that there is unhindered access to the lid in
order to be able to carry out work on the filter, e.g. cleaning the
filter sponges.
– Never operate the Filtoclear pressure filter with integrated
UVC with a water pressure greater than 2,9 psi ( 0,2 bar). The
height difference between the lid and pressure-free outlet can
therefore be a maximum of 6,5 feet.
Connecting hoses
Decide which hose diameter you need based on the selection
table and the recommended hose according to the installation
guidelines for the clear water guarantee (page 9 and 10). Only
operate the Filtoclear with pressure hoses that are approved for a
pressure of at least 2,9 psi ( 0,2 bar) i.e. the maximum pressure
of the pump. From the OASE range, we recommend the green
spiral hose with the corresponding hose clip.
Note: We recommend warming the hose with hot water, pushing
/ twisting it onto the spiral stepped hose adapter and securing it
with a hose clip. This makes the connection more watertight.
Important!: To avoid pressure loss, cut the spiral stepped hose
adapter at the relevant point to fit each hose (see illustration).