Replacing Foam Filters; Storage/Over-Wintering - Oase BioTec ScreenMatic2 Serie Instrucciones De Uso

Ocultar thumbs Ver también para BioTec ScreenMatic2 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 67
How to proceed:
 O
1. Remove the screw for fastening the control device, remove the control device and place it carefully to the
side.
– If necessary, disconnect the motor cable plug from the control device.
– Mark the position of the control device on a side section for reassembly.
2. Take the ScreenMatic rotating screen unit out of the screen holder.
– Biotec ScreenMatic
rotating screen unit.
– Biotec ScreenMatic
tributor and remove.
3. Undo the nuts on the side section, and remove the side section and stripper.
4. Release the clamping lever and remove the ScreenMatic screen.
– Thoroughly clean the stripper.
– Thoroughly clean both sides of the ScreenMatic screen. Replace the ScreenMatic screen if necessary.
– Use the pump cleaning agent PumpClean from OASE.
5. Reassemble the ScreenMatic rotating screen unit in the reverse order and place it into the screen holder.
– When tensioning the ScreenMatic screen, ensure that the clamping lever engages.
8.5

Replacing foam filters

Prerequisite:
• The filter pump is switched off.
• The container is open. (→ Opening the container)
• The screen holder is hinged up. (→ Hinging the screen holder up/down)
How to proceed:
 O
1. Press both locking clips on the foam holder.
2. Remove the foam holder plate and foam filter.
3. Push a new foam filter onto the foam holder, fit the foam holder plate and push down until the two locking
clips engage in the foam holder plate.
Note!
Recommendation regarding the replacement of foam filters:
• Only partially replace the foam filters at intervals of at least a week so as not to impair the biological clean-
ing action too much.
• Never replace more than 50 % of the foam filters at any one time.
9

Storage/Over-wintering

The unit is protected from frost:
The unit can be operated as long as the water temperature does not go below +4 °C.
The deeper areas of the pond have a water temperature of approx. +4 °C in winter and are essential for the
fish. By taking the following measures it is possible to reduce the cooling effect on the water of the circulation
by the filter system:
• Position the pump nearer to the surface of the water so that only colder water closer to the surface of the
pond enters the pump.
• Insulate the return pipes from the filter system into the pond.
• Do not allow water to flow into the pond via a water course.
The unit is not protected from frost:
Take the unit out of operation at water temperatures below +8° C or, at the latest, when freezing temperatures
are to be expected.
• Drain the unit as far as possible, clean thoroughly and check for damage.
• Empty all hoses, pipes and connections as far as possible.
• Leave the slide valves open.
• Cover the filter container to prevent the penetration of rain water.
• Protect pipes and slide valves that are in contact with water from frost.
2
40000/60000: Press the locking clips on both sides and remove the ScreenMatic
2
140000: Press the ScreenMatic rotating screen unit in the direction of the water dis-
- EN -
37

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Biotec screenmatic2 40000Biotec screenmatic2 60000Biotec screenmatic2 140000

Tabla de contenido