Time-Dependent Cleaning; Ambient Temperature; System Messages - Oase BioTec ScreenMatic2 Serie Instrucciones De Uso

Ocultar thumbs Ver también para BioTec ScreenMatic2 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 67
- EN -
6.4

Time-dependent cleaning

The ScreenMatic rotating screen unit executes a cleaning cycle after a set interval depending on the ambient
temperature. This ensures cleaning at regular intervals
• if the sensor is soiled or defective,
• if there is very little soiling on the screen and/or low flow rates (e.g. when the SFC of the filter pump is acti-
vated).

Ambient temperature

≤10 °C
10 °C ... 20 °C
≥20 °C
6.5

System messages

LED
Malfunction
Flashes
No automatic cleaning cy-
green/red
cle within 48 hours
No flow of water
No water detected by the
sensor
Flashes red
20 automatic cleaning cy-
cles in succession
Flashes green
ScreenMatic screen not ro-
tating although a manual
cleaning cycle was trig-
gered.
Off
ScreenMatic screen not ro-
tating although a manual
cleaning cycle was trig-
gered.
34
Interval
6 hours
4 hours
3 hours
Possible cause
Sensor soiled
Filter pump is not operating
Control device incorrectly posi-
tioned
Control device defective
Insufficient conductivity of the
water
Insufficient pump capacity
ScreenMatic screen soiled
Sensor soiled
Control device incorrectly posi-
tioned
Pump capacity too high
Motor cable plug not connected
or incorrectly connected to the
control device
Motor defective
Connection cable plug not con-
nected or incorrectly connected
to the transformer
Transformer not connected to
the mains voltage
Transformer defective
Control device defective
Rotational movement of the ScreenMatic screen
One rotation forward
• The debris is conveyed into the debris tray.
Remedy
– Clean the sensor.
– Descale the sensor.
Start up the filter pump.
Correctly position the control de-
vice
Replace the control device.
Increase the water hardness with
OptiPond
Adjust the pump capacity accord-
ingly
– Start manual the cleaning
cycle and use a brush to
clean the ScreenMatic
screen on the side of the
water distributor (→ Manual
cleaning)
– Clean the ScreenMatic
screen from the inside if the
mesh is clogged by a bio-
film (→ Cleaning/replacing
the ScreenMatic screen)
Clean the sensor.
Correctly position the control de-
vice
Adjust the pump capacity accord-
ingly
Connect the plug, check that it is
correctly seated.
Replace motor
Connect the plug, check that it is
correctly seated.
Connect the transformer to the
mains voltage.
Replace transformer
Replace the control device.
Resetting the system
message
Automatic reset after rem-
edy of malfunction
Automatic reset after rem-
edy of malfunction

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Biotec screenmatic2 40000Biotec screenmatic2 60000Biotec screenmatic2 140000

Tabla de contenido