3.5.1

Opening the container

 D
• BioTec ScreenMatic² 40000/60000: Release the locking clips, lift up the cover and remove.
• BioTec ScreenMatic² 140000: Lift the cover using the handles and remove.
– Screw the handles onto the cover. The handles are not fitted on delivery.
Note!
Only operate the unit with the container cover in place.
3.5.2

Hinging the screen holder up/down

How to proceed:
 E
To hinge up/open
1. Remove the debris tray.
2. Hinge up the distributor extension.
3. Hinge up the screen holder with the ScreenMatic rotating screen unit.
To hinge down/close
4. Carefully hinge down the screen holder.
5. Push the distribution extension down until it audibly engages.
6. Replace the debris tray.
4

Installation and connection

4.1

Installation planning

 F, G
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injuries caused by electric shock from electrical units operated in
or near water.
Protective measures for accessible ponds:
• Only use electrical units or installations with a rated voltage of U
• Electrical installations with a rated voltage of U
least 2 m from the water.
Protective measures for non-accessible ponds:
• Electrical installations with a rated voltage of U
least 2 m from the water.
Note:
Use suitable transport and lifting aids to transport and install the unit.
The unit weighs more than 25 kg. (→ Technical data)
Distance from the pond
Electrical components of the filter system operate with a rated voltage of U
supplied via an external transformer connected to the mains.
• Filter system without UVC clarifier fitted:
– The filter system can be installed directly next to the water. No minimum distances apply. The trans-
former must be located at a distance of at least 2 m from the water.
• Ponds that can be accessed by persons, filter systems with UVC clarifier fitted:
– The filter system and transformer must be located at a distance of at least 2 m from the water.
• Ponds that cannot be accessed by persons, filter systems with OASE UVC clarifier of the Bitron Eco series:
– The filter system may be installed directly next to the water No minimum distances apply. The trans-
former must be located at a distance of at least 2 m from the water.
• Ponds that cannot be accessed by persons, filter systems with OASE UVC clarifier of the Bitron C or
Vitronic series:
– The filter system and transformer must be located at a distance of at least 2 m from the water.
≤ 12 V or U
AC
> 12 V or U
> 30 V must be located at a distance of at
AC
DC
> 12 V or U
> 30 V must be located at a distance of at
AC
DC
≤ 30 V in the water.
DC
 = 12 V. The supply voltage is
DC