Descripciones de parámetros
10-11 Process Data Config Write
Seleccionar la escritura de datos de proceso para los elementos
de montaje de E/S 101/151. Pueden seleccionarse los elementos
[2] y [3] de esta matriz. Los elementos [0] y [1] son fijos.
Option:
[597]
Pulse Out #X30/6 Bus Control
[653]
Term 42 Output Bus Ctrl
[663]
Terminal X30/8 Bus Control
[673]
Terminal X45/1 Bus Control
[683]
Terminal X45/3 Bus Control
[748]
PCD Feed Forward
[890]
Bus Jog 1 Speed
[891]
Bus Jog 2 Speed
[1680]
Fieldbus CTW 1
[1682]
Fieldbus REF 1
[1685]
FC Port CTW 1
[1686]
FC Port REF 1
[3310]
Sync Factor Master
[3311]
Sync Factor Slave
[3401]
PCD 1 Write to MCO
[3402]
PCD 2 Write to MCO
[3403]
PCD 3 Write to MCO
[3404]
PCD 4 Write to MCO
[3405]
PCD 5 Write to MCO
[3406]
PCD 6 Write to MCO
[3407]
PCD 7 Write to MCO
[3408]
PCD 8 Write to MCO
[3409]
PCD 9 Write to MCO
[3410]
PCD 10 Write to MCO
10-12 Process Data Config Read
Seleccionar los datos de lectura de proceso para los montajes de
entradas/salidas 101/151 Pueden seleccionarse los elementos [2]
y [3] de esta matriz. Los elementos [0] y [1] de la matriz son fijos.
Option:
[0]
None
*
[15]
Readout: actual setup
[1472]
Legacy Alarm Word
[1473]
Legacy Warning Word
[1474]
Leg. Ext. Status Word
[1500]
Operating Hours
[1501]
Running Hours
[1502]
kWh Counter
[1600]
Control Word
[1601]
Reference [Unit]
[1602]
Reference %
[1603]
Status Word
[1605]
Main Actual Value [%]
[1609]
Custom Readout
[1610]
Power [kW]
[1611]
Power [hp]
[1612]
Motor Voltage
[1613]
Frequency
[1614]
Motor Current
Guía de programación del FC 300
Función:
[1615]
[1616]
[1617]
[1618]
[1619]
[1620]
[1621]
[1622]
[1625]
[1630]
[1632]
[1633]
[1634]
[1635]
[1638]
[1639]
[1650]
[1651]
[1652]
[1653]
[1657]
[1660]
[1661]
[1662]
[1663]
[1664]
[1665]
[1666]
[1667]
Función:
[1668]
[1669]
[1670]
[1671]
[1672]
[1673]
[1674]
[1675]
[1676]
[1677]
[1678]
[1679]
[1684]
[1690]
[1691]
[1692]
[1693]
[1694]
[1860]
[3421]
®
MG33MD05 - VLT
es una marca registrada de Danfoss.
10-12 Process Data Config Read
Seleccionar los datos de lectura de proceso para los montajes de
entradas/salidas 101/151 Pueden seleccionarse los elementos [2]
y [3] de esta matriz. Los elementos [0] y [1] de la matriz son fijos.
Option:
Frequency [%]
Torque [Nm]
Speed [RPM]
Motor Thermal
KTY sensor temperature
Motor Angle
Torque [%] High Res.
Torque [%]
Torque [Nm] High
DC Link Voltage
Brake Energy /s
Brake Energy /2 min
Heatsink Temp.
Inverter Thermal
SL Controller State
Control Card Temp.
External Reference
Pulse Reference
Feedback [Unit]
Digi Pot Reference
Feedback [RPM]
Digital Input
Terminal 53 Switch Setting
Analog Input 53
Terminal 54 Switch Setting
Analog Input 54
Analog Output 42 [mA]
Digital Output [bin]
Freq. Input #29 [Hz]
Freq. Input #33 [Hz]
Pulse Output #27 [Hz]
Pulse Output #29 [Hz]
Relay Output [bin]
Counter A
Counter B
Prec. Stop Counter
Analog In X30/11
Analog In X30/12
Analog Out X30/8 [mA]
Analog Out X45/1 [mA]
Analog Out X45/3 [mA]
Comm. Option STW
Alarm Word
Alarm Word 2
Warning Word
Warning Word 2
Ext. Status Word
Digital Input 2
PCD 1 Read from MCO
Función:
3
3
127