Descripciones de parámetros
13-44 Logic Rule Boolean 3
Matriz [6]
Option:
[37]
Digital input DI32
[38]
Digital input DI33
3
3
[39]
Start command
[40]
Drive stopped
[41]
Reset Trip
[42]
Auto-reset Trip
[43]
Ok key
[44]
Reset key
[45]
Left key
[46]
Right key
[47]
Up key
[48]
Down key
[50]
Comparator 4
[51]
Comparator 5
[60]
Logic rule 4
[61]
Logic rule 5
[70]
SL Time-out 3
[71]
SL Time-out 4
[72]
SL Time-out 5
[73]
SL Time-out 6
[74]
SL Time-out 7
[75]
Start command given
[76]
Digital input x30/2
[77]
Digital input x30/3
[78]
Digital input x30/4
[79]
Digital input x46/1
[80]
Digital input x46/3
[81]
Digital input x46/5
[82]
Digital input x46/7
[83]
Digital input x46/9
[84]
Digital input x46/11
[85]
Digital input x46/13
[90]
ATEX ETR cur. warning
[91]
ATEX ETR cur. alarm
[92]
ATEX ETR freq. warning Seleccionable si 1-90 Motor
[93]
ATEX ETR freq. alarm
148
Guía de programación del FC 300
Función:
Seleccionable si 1-90 Motor
Thermal Protection está ajustada
en [20] o [21]. Si la alarma 164
ATEX ETR alarma lím.int. está
activa, la salida será 1.
Seleccionable si 1-90 Motor
Thermal Protection está ajustada
en [20] o [21]. Si la alarma 166
ATEX ETR alarma lím.frec. está
activa, la salida será 1.
Thermal Protection está ajustada
en [20] o [21] ]. Si la alarma 163
ATEX ETR advertencia lím.int. está
activa, la salida será 1.
Seleccionable si 1-90 Motor
Thermal Protection está ajustada
en [20] o [21]. Si la alarma 165
®
MG33MD05 - VLT
es una marca registrada de Danfoss.
13-44 Logic Rule Boolean 3
Matriz [6]
Option:
[94]
RS Flipflop 0
[95]
RS Flipflop 1
[96]
RS Flipflop 2
[97]
RS Flipflop 3
[98]
RS Flipflop 4
[99]
RS Flipflop 5
[100] RS Flipflop 6
[101] RS Flipflop 7
3.14.7 13-5* Estados
13-51 SL Controller Event
Matriz [20]
Option:
[0]
False
*
[1]
True
[2]
Running
[3]
In range
[4]
On reference
[5]
Torque limit
[6]
Current limit
[7]
Out of current range
[8]
Below I low
[9]
Above I high
[10]
Out of speed range
[11]
Below speed low
[12]
Above speed high
[13]
Out of feedb. range
[14]
Below feedb. low
[15]
Above feedb. high
[16]
Thermal warning
[17]
Mains out of range
[18]
Reversing
[19]
Warning
[20]
Alarm (trip)
[21]
Alarm (trip lock)
[22]
Comparator 0
[23]
Comparator 1
[24]
Comparator 2
[25]
Comparator 3
[26]
Logic rule 0
[27]
Logic rule 1
Función:
ATEX ETR advertencia lím.frec.
está activa, la salida será 1.
Función:
Seleccione la entrada booleana
(VERDADERO o FALSO) para
definir el evento de Smart Logic
Controller. Véae 13-01 Start Event
([0] - [61]) y 13-02 Stop Event ([70]
- [74]) para obtener una
descripción más detallada.