DSW5 Photocell intervention in the opening phase: if the photocell beam is interrupted, the motor is stopped. The operation starts again as soon as the
photocell beam is no longer obscured.
OFF: Disabled
ON: Enabled
DSW6 "Pedestrian" function: the input "Open" controls the partial opening (adjustable from approx. 1.5 to 10 metres)
OFF: Disabled
ON: Enabled
DSW7 Operating mode of the "Pedestrian" function
OFF: The input "Open" controls only the opening phase
ON: The input "Open" has the same functions as the input "P.P."
DSW8 Operating mode of the "Indicator lamp of open gate"
OFF: Normal operation ON/OFF
ON: Flashing operation: in the opening phase the indicator lamp flashes slowly. At completion of the opening, the indicator is on with fixed light, while
in the closing phase it flashes quickly.
Programmable functions - table 5
The functions for which it is possible to make a selection among a range of values are preset by using the programming push button (PROG.) together with
the dip-switches. The preset values are indicated with "(def.)"
In order to store the programmable functions in memory, position the dip-switches as indicated in the table, then press the button "PROG" for at least 2
seconds. The LED "PROG" switches off and then switches on again for about 2 seconds to confirm that the values have been stored in memory.
Once the programming is completed, move the dip-switched to the original positions.
Programming example
To reduce the preset default operating time of 220 seconds to 120 seconds, proceed as follows:
•
Preset the programming dip-switches as follows:
Variable selection of "Operating time" (table 5, part 1).
•
Press the programming button for at least 2 seconds until the programming LED switches off and then on again with fixed light for 2 seconds.
The LED will start flashing to indicate the normal operation.
•
Move the 8 dip-switches to the desired position for the presetting of the functions shown in table 4.
Function - part 1
Menu 1
Dip-switch 1÷4= On/Off/Off/Off
Dwell time for the automatic
closure.
Dip-switch 1÷4= On/On/Off/Off
The dwell time is reset if the contact of the
input FTC is open or the contact of the input
Open remains closed.
Closure distance.
Dip-switch 1÷4= Off/On/On/Off
N.B.: After changing this para-
meter, it is necessary to adjust the gate
stroke in order to render the changes
operative.
Continued ...
8
ON
1 2 3 4 5 6 7 8
Dip-switch5= Flashing during the dwell time for the automatic closure.
ON
Off: Flashing light off (def.)
On: Flashing light on
1
2
3
4
Dip-switch6= Decrease of the automatic closure time after obscuring the photocell beam.
Off: No change (def.)
On: The closure time is reduced to º of the total value (minimum time=5 seconds)
Dip-switch7= Automatic closure in the event of stop with the "P.P:" button in the opening phase
Off: Automatic closure disabled (def.)
On: Automatic closure enabled
Dip-switch8= Rev. sensor. Do not activate this function if the motor is not provided with rev. sensor.
Off: Enabled (def.)
On: Disabled
ON
1
2
3
4
Dip-switch5= Off
ON
1
2
3
4
Continued ...
Selection of time: 120 seconds (table 5 part2).
Table 5
Selectable values - part 2
Dsw5
Dsw6
Dsw7
Dsw8
Off
Off
Off
Off
On
Off
Off
Off
Off
On
Off
Off
On
On
Off
Off
Off
Off
On
Off
On
Off
On
Off
Off
On
On
Off
On
On
On
Off
Off
Off
Off
On
On
Off
Off
On
Off
On
Off
On
On
On
Off
On
Off
Off
On
On
On
Off
On
On
Off
On
On
On
On
On
On
On
Dsw6
Dsw7
Dsw8
Closure distance
On
On
On
3,5 cm
Off
On
On
3 cm
On
Off
On
2,5 cm
Off
Off
On
2 cm
On
On
Off
2,5 cm
Off
On
Off
1 cm (def.)
On
Off
Off
0,5 cm
Off
Off
Off
0 cm
Seconds
5
10
15
20
30
40
50
60
80
100
120
140
160
180
200
220 (def.)