Atlas Copco Dynapac SD1800C Manejo Y Mantenimiento página 220

Terminadora de firmes
Tabla de contenido

Publicidad

KWP
SPN
FMI
1019
51
3
1020
51
4
1021
51
12
1022
51
6
1023
51
5
1024
51
3
1025
51
4
1026
4769
2
1029
4766
0
1032
4766
1
1034
4769
3
1035
4769
4
1036
4768
2
1039
4765
0
1042
4765
1
1044
4768
3
1045
4768
4
1047
3248
4
1066
1180
11
1067
1180
3
D 23.18 64
Code
Error Identification
5-9-4
Actuator error EGR-Valve (2.9;3.6) or
Throttle-Valve (6.1,7.8); internal error
5-9-4
Actuator error EGR-Valve (2.9;3.6) or
Throttle-Valve (6.1,7.8); internal error
5-9-4
Actuator error EGR-Valve (2.9;3.6) or
Throttle-Valve (6.1,7.8); internal error
5-9-4
Actuator error EGR-Valve (2.9;3.6) or
Throttle-Valve (6.1,7.8); internal error
5-9-4
Actuator error EGR-Valve (2.9;3.6) or
Throttle-Valve (6.1,7.8); internal error
5-9-4
Actuator error EGR-Valve (2.9;3.6) or
Throttle-Valve (6.1,7.8); internal error
5-9-4
Actuator error EGR-Valve (2.9;3.6) or
Throttle-Valve (6.1,7.8); internal error
6-8-4
Sensor exhaust gas temperature down-
stream (DOC); plausibility error
6-8-4
Physical range check high for exhaust
gas temperature downstream (DOC)
6-8-4
Physical range check low for exhaust
gas temperature downstream (DOC)
6-8-4
Sensor error exhaust gas temperature
downstream (DOC); signal range check
high
6-8-4
Sensor error exhaust gas temperature
downstream (DOC); signal range check
low
6-8-3
Sensor exhaust gas temperature
upstream (DOC); plausibility error
6-8-3
Physical range check high for exhaust
gas temperature upstream (DOC)
6-8-3
Physical range check low for exhaust
gas temperature upstream (DOC)
6-8-3
Sensor error exhaust gas temperature
upstream (DOC); signal range check
high
6-8-3
Sensor error exhaust gas temperature
upstream (DOC); signal range check low
6-8-5
Sensor error particle filter downstream
temperature; signal range check low
5-5-6
Sensor exhaust gas temperature
upstream turbine; plausibility error
5-5-6
Sensor error exhaust gas temperature
upstream turbine; signal range check
high
Short Text Detail
EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8);
short circuit to battery
EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8);
short circuit to ground
Mechanical actuator defect EGR-Valve
(2.9,3.6) or Throttle-Valve (6.1,7.8)
Actuator error EGR-Valve (2.9;3.6) or Throttle-
Valve (6.1,7.8); signal range check high
Actuator error EGR-Valve (2.9;3.6) or Throttle-
Valve (6.1,7.8); signal range check low
Position sensor error of actuator EGR-Valve
(2.9;3.6) or Throttle-Valve (6.1,7.8); signal
range check high
Position sensor error actuator EGR-Valve
(2.9;3.6) or Throttle-Valve (6.1,7.8); signal
range check low
Sensor exhaust gas temperature downstream
(DOC); plausibility error
Physical range check high for exhaust gas tem-
perature downstream (DOC)
Physical range check low for exhaust gas tem-
perature downstream (DOC)
Sensor error exhaust gas temperature down-
stream (DOC); signal range check high
Sensor error exhaust gas temperature down-
stream (DOC); signal range check low
Sensor exhaust gas temperature upstream
(DOC); plausibility error
Physical range check high for exhaust gas tem-
perature upstream (DOC)
Physical range check low for exhaust gas tem-
perature upstream (DOC)
Sensor error exhaust gas temperature
upstream (DOC); signal range check high
Sensor error exhaust gas temperature
upstream (DOC); signal range check low
Sensor error particle filter downstream temper-
ature; signal range check low
Sensor exhaust gas temperature upstream tur-
bine; plausibility error
Sensor error exhaust gas temperature
upstream turbine; signal range check high

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dynapac 911

Tabla de contenido