Atlas Copco Dynapac SD1800C Manejo Y Mantenimiento página 262

Terminadora de firmes
Tabla de contenido

Publicidad

KWP
SPN
FMI
1422
1
56
7
1255
7
1254
1
1259
2
1260
2
1258
11
1265
12
1266
12
1219
14
1247
11
57
14
1263
11
1220
14
1221
14
1302
11
1481
5
805
14
1431
2
1432
2
1440
7
1441
13
1442
2
D 23.18 106
Code
Error Identification
7-7-2
Zerofuel calibration injector 8 (in firing
order); minimum value exceeded
8-5-6
Burner operation disturbed
8-5-7
Burner operation disturbed
8-5-8
Air pressure glow plug flush line; below
limit
8-5-9
Air Pump; air flow is not plausible
8-5-9
Air Pump; air flow is not plausible
8-5-9
HFM sensor; electrical fault
8-6-0
Spark plug control unit (SPCU); internal
error
8-6-1
Spark plug control unit (SPCU); internal
error
7-8-6
DPF wasn´t regenerated, power reduc-
tion phase 1 (manuell regeneration
request)
8-6-2
Air Pump; air lines blocked
8-6-3
Engine power; Not enough oxygen for
regeneration
8-6-4
Burner fuel line pipe leak behind Shut Off
Valve
7-8-6
DPF wasn´t regenerated, power reduc-
tion phase 2 (manuell regeneration
request)
7-8-6
DPF wasn´t regenerated, warning condi-
tion (manuell regeneration mode)
8-6-6
Deviation of the exhaust gas tempera-
ture setpoint to actual value downstream
(DOC) too high
DPF system; operating voltage error
Particulate filter; regeneration not suc-
cesful
8-1-5
CAN message PROEGRActr; plausibil-
ity error
8-1-5
Timeout Error of CAN-Receive-Frame
ComEGRActr - exhaust gas recircula-
tion positioner
EGR actuator; internal error
EGR actuator; calibration error
EGR actuator; status message "EGR-
Cust" is missing
Short Text Detail
Zerofuel calibration injector 8 (in firing order);
minimum value exceeded
Burner flame unintentional deleted
Burner operation is interrupted too often
Air pressure glow plug flush line; below limit
Amount of air is not plausible to pump speed
Calculated amount of air is not plausible to
HFM reading
HFM sensor; electrical fault
Spark plug control unit (SPCU); electrical fault
Spark plug control unit (SPCU); internal error
DPF wasn´t regenerated, power reduction
phase 1 (manuell regeneration request)
Air Pump; air lines blocked
Engine power; Not enough oxygen for regener-
ation
Burner fuel line pipe leak behind Shut Off Valve
DPF wasn´t regenerated, power reduction
phase 2 (manuell regeneration request)
DPF wasn´t regenerated, warning condition
(manuell regeneration mode)
Deviation of the exhaust gas temperature set-
point to actual value downstream (DOC) too
high
DPF system; operating voltage error
Particulate filter; regeneration not succesful
CAN message PROEGRActr; plausibility error
Timeout Error of CAN-Receive-Frame ComE-
GRActr - exhaust gas recirculation positioner
EGR actuator; internal error
EGR actuator; calibration error
EGR actuator; status message "EGRCust" is
missing