Atlas Copco Dynapac SD1800C Manejo Y Mantenimiento página 226

Terminadora de firmes
Tabla de contenido

Publicidad

KWP
SPN
FMI
1257
523915
7
1258
524016
11
1259
524016
2
1260
524016
2
1261
523910
6
1262
523922
7
1263
524021
11
1264
523922
7
1265
524017
12
1266
524017
12
1267
523989
0
1268
523990
0
1269
523989
1
1270
523990
1
1279
523992
9
1283
523993
9
1285
524038
9
1286
524039
9
1287
524040
9
1288
524041
9
1289
524042
9
D 23.18 70
Code
Error Identification
8-5-3
HCI dosing valve (DV1); blocked
8-5-9
HFM sensor; electrical fault
8-5-9
Air Pump; air flow is not plausible
8-5-9
Air Pump; air flow is not plausible
6-9-5
Air Pump; over current
8-5-4
Shut off valve: blocked
8-6-4
Burner fuel line pipe leak behind Shut Off
Valve
8-5-5
Shut off valve: blocked
8-6-0
Spark plug control unit (SPCU); internal
error
8-6-1
Spark plug control unit (SPCU); internal
error
7-2-4
Fuel Balance Control integrator injector 7
(in firing order); maximum value
exceeded
7-2-4
Fuel Balance Control integrator injector 8
(in firing order); maximum value
exceeded
7-2-4
Fuel Balance Control integrator injector 7
(in firing order); minimum value
exceeded
7-2-4
Fuel Balance Control integrator injector 8
(in firing order); minimum value
exceeded
Timeout Error of CAN-Receive-Frame
DM19Vol1; NOX sensor upstream
Timeout Error of CAN-Receive-Frame
DM19Vol2; NOX sensor downstream
Timeout error of CAN-Receive-Frame
ComMS_Sys1TO (error memory Slave);
Master-Slave internal CAN message
Timeout error of CAN-Receive-Frame
ComMS_Sys2TO (error memory Slave);
Master-Slave internal CAN message
Timeout error of CAN-Receive-Frame
ComMS_Sys3TO (error memory Slave);
Master-Slave internal CAN message
Timeout error of CAN-Receive-Frame
ComMS_Sys4TO (error memory Slave);
Master-Slave internal CAN message
Timeout error of CAN-Receive-Frame
ComMS_Sys5TO (error memory Slave);
Master-Slave internal CAN message
Short Text Detail
HCI dosing valve (DV1); blocked open
HFM sensor; electrical fault
Amount of air is not plausible to pump speed
Calculated amount of air is not plausible to
HFM reading
Air Pump; over current
Burner Shut Off Valve; blocked closed
Burner fuel line pipe leak behind Shut Off Valve
Burner Shut Off Valve; blocked open
Spark plug control unit (SPCU); electrical fault
Spark plug control unit (SPCU); internal error
Fuel Balance Control integrator injector 7 (in fir-
ing order); maximum value exceeded
Fuel Balance Control integrator injector 8 (in fir-
ing order); maximum value exceeded
Fuel Balance Control integrator injector 7 (in fir-
ing order); minimum value exceeded
Fuel Balance Control integrator injector 8 (in fir-
ing order); minimum value exceeded
Timeout Error of CAN-Receive-Frame
DM19Vol1; NOX sensor upstream
Timeout Error of CAN-Receive-Frame
DM19Vol2; NOX sensor downstream
Timeout error of CAN-Receive-Frame
ComMS_Sys1TO (error memory Slave); Mas-
ter-Slave internal CAN message
Timeout error of CAN-Receive-Frame
ComMS_Sys2TO (error memory Slave); Mas-
ter-Slave internal CAN message
Timeout error of CAN-Receive-Frame
ComMS_Sys3TO (error memory Slave); Mas-
ter-Slave internal CAN message
Timeout error of CAN-Receive-Frame
ComMS_Sys4TO (error memory Slave); Mas-
ter-Slave internal CAN message
Timeout error of CAN-Receive-Frame
ComMS_Sys5TO (error memory Slave); Mas-
ter-Slave internal CAN message

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dynapac 911

Tabla de contenido