Atlas Copco Dynapac SD1800C Manejo Y Mantenimiento página 221

Terminadora de firmes
Tabla de contenido

Publicidad

KWP
SPN
FMI
1068
1180
4
1069
4361
0
1070
4361
1
1072
4361
3
1073
4361
4
1074
1761
14
1077
3361
3
1078
3361
3
1079
3361
4
1080
3361
4
1081
4345
5
1082
4366
5
1083
4343
5
1084
4366
5
1085
4366
5
1086
4341
5
1087
523719
5
1088
4366
5
1089
4243
11
1090
4345
5
1092
4345
3
1093
4345
4
Code
Error Identification
5-5-6
Sensor error exhaust gas temperature
upstream turbine; signal range check low
6-6-8
Physical range check high for urea cata-
lyst upstream temperature
6-6-8
Physical range low for urea catalyst
upstream temperature
6-6-8
Sensor error urea catalyst exhaust gas
temperature upstream; signal range
check high
6-6-8
Sensor error urea catalyst exhaust gas
temperature upstream; signal range
check low
6-7-0
Urea tank level; warning threshold
exceeded
6-7-7
Urea dosing valve; short circuit to battery
6-7-7
Urea dosing valve; short circuit to battery
6-7-7
Urea dosing valve; short circuit to ground
6-7-7
Urea dosing valve; short circuit to ground
6-7-4
SCR heater relay urea returnline; open
load
7-6-2
SCR main relay (secondary side): open
load
6-7-3
SCR heater relay urea pressureline;
open load
7-6-2
SCR main relay; short circuit
7-6-2
SCR main relay; short circuit
6-7-5
SCR heater relay urea supplyline; open
load
6-7-2
SCR heater relay urea supply module;
open load
6-7-1
SCR Tank heating valve; open load
7-8-3
SCR system heater diagnostic reports
error; shut off SCR-system
6-7-4
SCR heater relay urea returnline; open
load
6-7-4
SCR heater urea returnline; short circuit
to battery
6-7-4
SCR heater urea returnline; short circuit
to ground
Short Text Detail
Sensor error exhaust gas temperature
upstream turbine; signal range check low
Physical range check high for urea catalyst
upstream temperature
Physical range low for urea catalyst upstream
temperature
Sensor error urea catalyst exhaust gas temper-
ature upstream; signal range check high
Sensor error urea catalyst exhaust gas temper-
ature upstream; signal range check low
Urea tank level; warning threshold exceeded
Urea dosing valve; short circuit to battery on
high side
Urea dosing valve; short circuit to battery or
open load on high side
Urea dosing valve; short circuit to ground or
open load on low side
Urea dosing valve; short circuit on high side
SCR heater relay urea returnline sekondary
side; open load
SCR main relay (secondary side): open load
SCR heater relay urea pressureline secondary
side; open load
SCR main relay (secondary side); Shortcut to
battery
SCR main relay (secondary side); shortcut to
ground
SCR heater relay urea supplyline secondary
side; open load
SCR heater relay urea supply modul secondary
side; open load
SCR Tank heating valve secundary side: open
load
SCR system heater diagnostic reports error;
shut off SCR-system
SCR heater relay urea returnline primary side;
open load
SCR heater urea returnline; short circuit to bat-
tery
SCR heater urea returnline; short circuit to
ground
D 23.18 65

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dynapac 911

Tabla de contenido