Atlas Copco Dynapac SD1800C Manejo Y Mantenimiento página 230

Terminadora de firmes
Tabla de contenido

Publicidad

KWP
SPN
FMI
1420
524012
0
1421
524011
1
1422
524012
1
1431
524028
2
1432
524029
2
1436
524034
5
1437
524034
12
1438
524034
3
1439
524034
4
1440
524030
7
1441
524031
13
1442
524032
2
1443
524033
7
1444
2621
5
1445
2621
12
1446
2621
3
1447
2621
4
1448
175
0
1449
175
0
1453
411
0
1454
411
1
1455
3711
12
1457
524055
4
D 23.18 74
Code
Error Identification
7-7-2
Zerofuel calibration injector 8 (in firing
order); maximum value exceeded
7-7-2
Zerofuel calibration injector 7 (in firing
order); minimum value exceeded
7-7-2
Zerofuel calibration injector 8 (in firing
order); minimum value exceeded
8-1-5
CAN message PROEGRActr; plausibil-
ity error
8-1-5
Timeout Error of CAN-Receive-Frame
ComEGRActr - exhaust gas recircula-
tion positioner
8-1-6
Disc Separator; open load
8-1-6
Disc Separator; powerstage over tem-
perature
8-1-6
Disc separator; short circuit to battery
8-1-6
Disc separator; short circuit to ground
EGR actuator; internal error
EGR actuator; calibration error
EGR actuator; status message "EGR-
Cust" is missing
EGR actuator; due to overload in Save
Mode
Flush valve burner (EPV DPF-System);
open load
Flush valve burner (EPV DPF-System);
powerstage over temperature
Flush valve burner (EPV DPF-System);
short circuit to battery
Flush valve burner (EPV DPF-System);
short circuit to ground
1-4-4
Oil temperature; out of range, system
reaction initiated
1-4-4
Oil temperature; out of range, system
reaction initiated
Differential pressure Venturiunit (EGR);
warning threshold exceeded
Differential pressure Venturiunit (EGR);
shut off threshold exceeded
Regeneration temperature (PFltRgn Ligt-
Off) not reached; regeneration aborted
Spark Plug Control Unit (SPCU); short
circuit to ground
Short Text Detail
Zerofuel calibration injector 8 (in firing order);
maximum value exceeded
Zerofuel calibration injector 7 (in firing order);
minimum value exceeded
Zerofuel calibration injector 8 (in firing order);
minimum value exceeded
CAN message PROEGRActr; plausibility error
Timeout Error of CAN-Receive-Frame ComE-
GRActr - exhaust gas recirculation positioner
Disc Separator; open load
Disc Separator; powerstage over temperature
Disc separator; short circuit to battery
Disc separator; short circuit to ground
EGR actuator; internal error
EGR actuator; calibration error
EGR actuator; status message "EGRCust" is
missing
EGR actuator; due to overload in Save Mode
Flush valve burner (EPV DPF-System); open
load
Flush valve burner (EPV DPF-System); power-
stage over temperature
Flush valve burner (EPV DPF-System); short
circuit to battery
Flush valve burner (EPV DPF-System); short
circuit to ground
High customer oil temperature; warning thresh-
old exceeded
High customer oil temperature; shut off thresh-
old exceeded
Differential pressure Venturiunit (EGR); warn-
ing threshold exceeded
Differential pressure Venturiunit (EGR); shut off
threshold exceeded
Regeneration temperature (PFltRgn LigtOff)
not reached; regeneration aborted
Spark Plug Control Unit (SPCU); short circuit to
ground