Atlas Copco Dynapac SD1800C Manejo Y Mantenimiento página 255

Terminadora de firmes
Tabla de contenido

Publicidad

KWP
SPN
FMI
69
1
64
2
72
3
73
4
74
3
75
4
78
3
79
4
76
5
1216
5
1217
11
77
12
500
0
502
3
503
3
504
4
1256
7
1257
7
505
11
501
12
508
0
Code
Error Identification
7-2-2
Physical range check low for burner dos-
ing valve (DV2) downstream pressure;
shut off regeneration. When burner injec-
tor is actuated, the measured pressure
does not rise above ca. 1250mbar abs
(expected: ca. 2400mbar).
7-2-2
Burner dosing valve (DV2) downstream
pressure sensor; plausibility error
7-2-2
Sensor error burner dosing valve (DV2)
downstream pressure sensor; signal
range check high
7-2-2
Sensor error burner dosing valve (DV2)
downstream pressure sensor; signal
range check low
7-2-1
Sensor error glow plug control diagnostic
line voltage; signal range check high
7-2-1
Sensor error glow plug control diagnostic
line voltage; signal range check low
7-2-1
Glow plug control; short circuit to battery
7-2-1
Glow plug control; short circuit to ground
7-2-1
Glow plug control; open load
8-5-1
Glow plug control; open load
8-5-1
Glow plug control; internal error
7-2-1
Glow plug control; powerstage over tem-
perature
7-2-0
HCI dosing valve (DV1); overcurrent at
the end of the injection phase
7-2-0
HCI dosing valve (DV1); short circuit to
battery
7-2-0
HCI dosing valve (DV1); short circuit to
battery
7-2-0
HCI dosing valve (DV1); short circuit to
ground
8-5-2
HCI dosing valve (DV1); blocked
8-5-3
HCI dosing valve (DV1); blocked
7-2-0
HCI dosing valve (DV1); short circuit high
side powerstage
7-2-0
HCI dosing valve (DV1); powerstage
over temperature
7-1-9
Physical range check high for HCI dosing
valve (DV1) downstream pressure; shut
off regeneration
Short Text Detail
Physical range check low for burner dosing
valve (DV2) downstream pressure; shut off
regeneration. When burner injector is actuated,
the measured pressure does not rise above ca.
1250mbar abs (expected: ca. 2400mbar).
Burner dosing valve (DV2) downstream pres-
sure sensor; plausibility error
Sensor error burner dosing valve (DV2) down-
stream pressure sensor; signal range check
high
Sensor error burner dosing valve (DV2) down-
stream pressure sensor; signal range check
low
Sensor error glow plug control diagnostic line
voltage; signal range check high
Sensor error glow plug control diagnostic line
voltage; signal range check low
Glow plug control; short circuit to battery
Glow plug control; short circuit to ground
Glow plug control; open load
Glow plug control release line; short circuit
error
Glow plug control; internal error
Glow plug control; powerstage over tempera-
ture
HCI dosing valve (DV1); overcurrent at the end
of the injection phase
HCI dosing valve (DV1); short circuit to battery
HCI dosing valve (DV1); short circuit to battery
high side
HCI dosing valve (DV1); short circuit to ground
HCI dosing valve (DV1); blocked closed
HCI dosing valve (DV1); blocked open
HCI dosing valve (DV1); short circuit high side
powerstage
HCI dosing valve (DV1); powerstage over tem-
perature
Physical range check high for HCI dosing valve
(DV1) downstream pressure; shut off regenera-
tion
D 23.18 99