Atlas Copco Dynapac SD1800C Manejo Y Mantenimiento página 225

Terminadora de firmes
Tabla de contenido

Publicidad

KWP
SPN
FMI
1223
51
5
1224
51
6
1225
51
12
1226
51
3
1227
51
3
1228
51
4
1229
51
4
1230
51
6
1231
51
11
1232
51
4
1239
523984
3
1240
523985
3
1243
523988
5
1244
523988
12
1245
523988
3
1246
523988
4
1247
524019
11
1248
523910
9
1249
523910
7
1250
523910
12
1251
523910
0
1252
523910
0
1253
523911
7
1254
524014
1
1255
524013
7
1256
523915
7
Code
Error Identification
5-9-4
Actuator error EGR-Valve (2.9;3.6) or
Throttle-Valve (6.1,7.8); internal error
5-9-4
Actuator error EGR-Valve (2.9;3.6) or
Throttle-Valve (6.1,7.8); internal error
5-9-4
Actuator error EGR-Valve (2.9;3.6) or
Throttle-Valve (6.1,7.8); internal error
5-9-4
Actuator error EGR-Valve (2.9;3.6) or
Throttle-Valve (6.1,7.8); internal error
5-9-4
Actuator error EGR-Valve (2.9;3.6) or
Throttle-Valve (6.1,7.8); internal error
5-9-4
Actuator error EGR-Valve (2.9;3.6) or
Throttle-Valve (6.1,7.8); internal error
5-9-4
Actuator error EGR-Valve (2.9;3.6) or
Throttle-Valve (6.1,7.8); internal error
5-9-4
Actuator error EGR-Valve (2.9;3.6) or
Throttle-Valve (6.1,7.8); internal error
5-9-4
Actuator error EGR-Valve (2.9;3.6) or
Throttle-Valve (6.1,7.8); internal error
5-9-4
Actuator error EGR-Valve (2.9;3.6) or
Throttle-Valve (6.1,7.8); internal error
7-8-8
UB6; Short circuit to battery error of actu-
ator relay 6
7-8-9
UB7; Short circuit to battery error of actu-
ator relay 7
7-9-2
Charging lamp; open load
7-9-2
Charging lamp; over temperature
7-9-2
Charging lamp; short circuit to battery
7-9-2
Charging lamp; short circuit to ground
8-6-2
Air Pump; air lines blocked
6-9-5
Air Pump; CAN communication lost
6-9-5
Air pump; CAN communication inter-
rupted no purge function available
6-9-5
Air Pump; internal error
6-9-5
Air Pump; internal error
6-9-5
Air Pump; internal error
8-5-0
Burner dosing valve (DV2); blocked
closed
8-5-8
Air pressure glow plug flush line; below
limit
8-5-7
Burner operation disturbed
8-5-2
HCI dosing valve (DV1); blocked
Short Text Detail
Actuator EGR-Valve (2.9;3.6) or Throttle-Valve
(6.1,7.8); open load
Actuator EGR-Valve (2.9;3.6) or Throttle-Valve
(6.1,7.8); over current
Actuator EGR-Valve (2.9;3.6) or Throttle-Valve
(6.1,7.8); over temperature
EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8);
short circuit to battery (A02)
EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8);
short circuit to battery (A67)
EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8);
short circuit to ground (A02)
EGR-Valve (2.9;3.6) or Throttle-Valve (6.1,7.8);
short circuit to ground (A67)
Actuator error EGR-Valve (2.9;3.6) or Throttle-
Valve (6.1,7.8); Overload by short-circuit
Actuator error EGR-Valve (2.9;3.6) or Throttle-
Valve (6.1,7.8); Power stage overtemperature
due to high current
Actuator error EGR-Valve (2.9;3.6) or Throttle-
Valve (6.1,7.8); Voltage below threshold
UB6; Short circuit to battery error of actuator
relay 7
UB7; Short circuit to battery error of actuator
relay 8
Charging lamp; open load
Charging lamp; over temperature
Charging lamp; short circuit to battery
Charging lamp; short circuit to ground
Air Pump; air lines blocked
Air Pump; CAN communication lost
Air pump; CAN communication interrupted no
purge function available
Air Pump; internal error
Air Pump; powerstage over temperature
Air Pump; operating voltage error
Burner dosing valve (DV2); blocked closed
Air pressure glow plug flush line; below limit
Burner operation is interrupted too often
HCI dosing valve (DV1); blocked closed
D 23.18 69

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Dynapac 911

Tabla de contenido