Troubleshooting; Safety Notices; Fault Indications; Causes And Rectification Of Faults - CASO DESIGN IMCG25 Instrucciones De Funcionamiento Originales

Ocultar thumbs Ver también para IMCG25:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 151

16 Troubleshooting

This chapter provides you with important notices with regard to operating the device.
Observe the following notices to avoid dangers and damages:

16.1 Safety notices

Attention
► Only qualified electricians, who have been trained by the manufacturer, may carry out
any repairs on electrical equipment.
► Improperly performed repairs can cause considerable dangers for the user and
damages to the device.

16.2 Fault indications

In the event of a fault, an error code will appear in the display; it describes the cause of the
fault.
Error code
E01
Excessive temperature within cooking chamber
The overheating cut-out terminated the current program.
Press the Pause/Cancel button to acknowledge this fault.
The device can be re-activated after the cool down phase.
E02
Technical error
A technical error has occurred. Press the Pause/Cancel button to
acknowledge this fault. Please contact our Customer Service.
E03
Sensor fault
The device has detected an error on a sensor and has terminated the
current programme. Press the Pause/Cancel button to acknowledge this
fault.
► If error messages continue to appear after an extended waiting period and restarting the
device, then the device will need to be sent to Customer Service to be inspected.

16.3 Causes and rectification of faults

The following table assists in localizing and rectifying minor faults.
Error
The selected program will
not start.
Description
Please note
Possible cause
Device door is not closed
Power plug is not plugged in
Action
Close device door
Plug in mains plug!
78

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

3359