13
Move a little step down
06
Move to partial position 1
07
Move to partial position 2
08
Move to partial position 3
09
Move to partial position 4
10
Move to partial position 5
11
Move to partial position 6
Note – The available commands must also be available for the
motor.
5.5.1 – Move to partial position 1, 2, 3, 4, 5, 6
command
Moves the motor to the set position after the partial position
has been assigned.
Structure
Start
TT ADR
TT ENDPOINT
[XX]
[YY]
CMD
IND
04
The data field is empty.
Example
Start
TT ADR
TT ENDPOINT
[XX]
[YY]
CMD
01
04
Command
Data
CR
[AA]
06
Command
Data
CR
[AA]
06
Response
Start
TT ADR
TT ENDPOINT
[XX]
[YY]
RISP
01
04
5.5.2 – STOP command
Stops the motor.
Structure
Start
TT ADR
TT ENDPOINT
[XX]
[YY]
CMD
IND
04
The data field is empty.
Example
Start
TT ADR
TT ENDPOINT
[XX]
[YY]
CMD
01
04
Response
Start
TT ADR
TT ENDPOINT
[XX]
[YY]
RISP
01
04
Command
Data
CR
[AA]
06
Command
Data
CR
[AA]
03
Command
Data
CR
[AA]
06
Command
Data
CR
[AA]
06
English - 7