General Safety Precautions; Installation Warning; Technical Details; Ec Declaration Of Conformity - DITEC VIVAH Manual De Instalación

Tablero eléctrico para automación 24 v a 1 o 2 motores
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 42

GENERAL SAFETY PRECAUTIONS

GB
This installation manual is intended for professionally
competent personnel only.
The installation, the power connections and the settings must be
completed in conformity with Good Working Methods and with
the regulations in force. Before installing the product, carefully
read the instructions. Bad installation could be hazardous.
The packaging materials (plastic, polystyrene, etc.) should not
be discarded in the environment or left within reach of children,
as these are a potential source of hazard. Before beginning the
installation check that the product is in perfect condition.
Do not install the product in explosive areas and atmospheres:
the presence of flammable gas or fumes represents a serious
threat to safety.
The safety devices (photocells, sensitive edges, emergency stop,
etc.) must be installed taking into account: the provisions and
the directives in force, Good Working Methods, the installation
area, the functional logic of the system and the forces developed
by the motorised door or gate.
Before making power connections, check that the rating
corresponds to that of the mains supply A multipolar di-
sconnection switch with a contact opening gap of at least 3 mm
must be included in the mains supply. Check that upstream of the
electrical installation an adequate residual current circuit breaker
and an overcurrent cut out are fitted. When requested, connect
the motorised door or gate to an effective earthing system carried
out as indicated by current safety regulations. During installation,
maintenance and repair operations, cut off the power supply
before opening the cover to access the electrical parts.
To handle electronic parts, wear earthed antistatic con-
ductive bracelets. The manufacturer of the motorisation
declines all responsibility in the event of components which
are not compatible with the safe and correct operation of the
product. For repairs or replacements of products only original
spare parts must be used.

INSTALLATION WARNING

Secure the control panel permanently. Drill a hole into the lower
side of the container so as to run the cables through it. Secure
the cables, if they are accessible, by means of appropriate
gland plates (not provided by us). Keep the line and motor con-
ductors separate (at least 8 mm) from the control conductors at
the terminal board connection points (for example, by means
of clamps). Connect the line and motor protection conductors
(yellow-green) by means of the transformer and control panel
using the clamp provided. At the end of the installation to close
again the container.

EC DECLARATION OF CONFORMITY

Manufacturer:
DITEC S.p.A. via Mons. Banfi, 3
21042 Caronno Pertusella (VA) – ITALY.
Herewith declares that the control panel VIVAH is in conformity
with the provisions of the following EC directives:
Low Voltage Directive 73/23/EEC;
EMC Directive 89/336/EEC.
Caronno Pertusella,
21-10-2005
VIVAH - IP1776
Fermo Bressanini
(Chairman)
120

TECHNICAL DETAILS

Power supply
Fuse F1
Motors output
Accessories power
supply
Temperature
Protection degree
Dimensions
APPLICATIONS
All rights reserved
All data and specifications have been drawn up and checked
with the greatest care. The manufacturer cannot however take
any responsibility for eventual errors, omissions or incomplete
data due to technical or illustrative purposes.
12
186
238
VIVAH
VIVAHJ
230 V~ / 50-60 Hz 120 V~ / 50-60 Hz
F2A
F4A
24 V=
24 V=
2x12 A max
2x12 A max
24 V= / 0,5 A
24 V= / 0,5 A
-20° C / +55° C
-20° C / +55° C
IP55
IP55
238x357x120
238x357x120