Control Board (With GFI Filter Coil)
Follow the steps below:
1. Plug cord in and turn switch ON. Connect wires
to control board and ON/OFF switch. Meter on AC
Volts.
110-120 AC
V
-
Black to board
Black from power cord
ti13138a
2. Plug cord in and turn switch ON. Connect wires
to control board and ON/OFF switch. Meter on
AC Volts.
110-120 AC
V
-
Black to board
Black from power cord
ti13139a
313314D
3. Check motor thermal switch. Unplug thermal wires
White from power cord
4. Plug cord in and turn switch ON. Disconnect
White from power cord
Refer to Wiring Diagram, page 85, for more details.
Repair / Réparation / Reparación
(see table below for proper reading).
NOTE: Motor should be cooled down.
-
Resistance Table:
Ironman 300E
8.2k ohms
695
0 ohms
795
2k ohms
1095
3.9k ohms
1595
6.2k ohms
potentiometer and carefully create a short between
potentiometer terminals.
ti13141a
ti13140a
Control Board
41