Commissioning
The product is ready for operation as soon as it is installed and connected.
• Make sure that the operating conditions lie within the permitted ranges (tech-
nical data
chapter 13).
• Make sure that a slide gate (process valve) attached to the linear drive can be
positioned without hindrance.
• If necessary, adjust the linear drive adapter attached to the piston rod. This
setting serves to optimise the opening or closing reaction of the connected
process valve or penstock valve.
• Slowly pressurise the linear drive.
For slow start-up pressurisation use soft-start valve type HEL.
• At first, select a slow travel speed.
9
Operation
Warning
Fast moving parts can cause injury to people in the vicinity of the DFPI.
• Make sure that, in the positioning range:
– Nobody can place his/her hand in the path of moving components (e.g. by
providing a protective guard).
– There are no foreign objects in the path of the moving components.
It should not be possible to touch the DFPI until the mass has come to a com-
plete rest.
10
Maintenance and care
If used as intended in the operating instructions, the device will be maintenance-
free.
11
Disassembly and repair
Make sure that the following energy sources are switched off:
– electrical power supply
– compressed air supply.
1. Remove the slide gate from the piston rod.
2. Remove the screws on the flange of the processing valve or penstock valve.
3. Remove the drive (if necessary including mounting adapter and coupling exten-
sion).
Recommendation: Send the product to our repair service.
This way the fine tuning and tests that are required will be taken into particular
consideration.
Information about spare parts and accessories
12
Troubleshooting
Malfunction
Possible cause
Piston rod does not move in
Compressed air tubes inter-
the desired direction
changed
Displacement encoder cable
incorrectly connected at posi-
tioning controller or DFPI (e.g.
connections at pin 1 and pin 3
interchanged).
Fig. 11
www.festo.com/spareparts.
Remedy
Correct the tubing connection
Correct the connection
13
Technical data
DFPI-...-...-ND2P-E-P-G2
Based on standard
Type of mounting
Flange hole pattern
Width across flats, spanner flat on the
piston rod
Design
Cushioning
Mounting position
Mode of operation
Position sensing
Measuring principle of displacement
encoder
Operating voltage range
[V DC]
Max. operating voltage
[V DC]
Independent linearity
[% FS]
Hysteresis
[mm]
Repetition accuracy
[mm]
Resistance value of displacement encoder (on the T.E.P.) dependent on the stroke length
– š 290 mm
[kΩ]
– , 290 mm to 590 mm
[kΩ]
– , 590 mm to 990 mm
[kΩ]
Pneumatic connection
Operating pressure
[bar]
Nominal operating pressure
[bar]
Operating medium
Note on the operating medium
Max. cable length
[m]
Protection class - in mounted status
Stroke
[mm]
Stroke reserve
[mm]
Ambient temperature
[°C]
Use outdoors
Product weight
– Basic weight with 0 mm
[g]
stroke
– Additional weight per
[g]
10 mm stroke
– Additional weight of dis-
[g]
placement encoder per
10 mm
– Moving mass with 0 mm
[g]
stroke
– Additional weight of mov-
[g]
ing load per 10 mm
stroke
Materials information
– Cylinder barrel
– Cap (end cap)
– Bottom cap (bearing cap)
– Piston rod
– Screws
– Seals
Note on materials
Vibration resistance
in accordance with DIN/IEC 68, Part
2-6
Continuous shock resistance
in accordance with DIN/IEC 68
Part 2-82
CE certification (see declaration of
conformity
www.festo.com)
1) T.E.P. = theoretical electrical path
2) Nitrile rubber and polyurethane
3) The device is intended for use in an industrial environment. In residential areas, measures for radio
interference suppression may have to be taken.
Fig. 12
-100-
-125-
-160-
-200-
-250-
...
...
...
...
...
DIN 3358
on flange in accordance with DIN 3358
F07
F10
F10, F14
22
27
36
Piston rod, cylinder barrel
No cushioning
Any
Double-acting
Via proximity sensor, with integrated displacement
encoder
Analogue
0 ... 15
15
±0.04
0.33
±0.12
5
10
20
For tubing O.D. ∅ 8 mm
3 ... 8
6
Compressed air in accordance with ISO 8573-1:2010 [7:4:4]
Lubricated operation possible (required during
subsequent operation)
30
IP65, IP67, IP68, IP69K, NEMA 4
40 ... 990
3
4
–20 ... +60
C1 – weather-protected areas in accordance with
IEC 60654
3476
5530
6529
13 946
22 569
80
145
159
187
325
2
1228
1944
2250
4722
7059
27
52
87
Anodised wrought aluminium alloy
High-alloy stain-
less steel
Anodised
Cast aluminium painted
wrought alu-
minium alloy
High-alloy stainless steel
Steel
NBR,
NBR (nitrile rubber)
2)
PU
Contains PWIS (paint-wetting impairment substances),
RoHS-compliant
0.35 mm path at 10 ... 60 Hz;
5 g acceleration at 60 ... 150 Hz
±15 g at 6 ms duration,
1000 shocks per direction
3)
in accordance with EU EMC Directive
-320-
...
1)
35 359
399
11417

Publicidad