EdilKamin SIDE Serie Instalación Uso Y Mantenimiento página 23

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 41
AIR FOR HEATING
AIR FOR HEATING
• •
CIRCULATION
CIRCULATION BY NATURAL CONVECTION
BY NATURAL CONVECTION
The environmental air enters from the side vents (12 12 - fi g. 1
The environmental air enters from the side vents (
on page 3) made in the base of the shell, it is heated, it rises by
on page 3) made in the base of the shell, it is heated, it rises by
convention along the cavity at the back of the fi replace and is
convention along the cavity at the back of the fi replace and is
released, hot, from the vents on the cover of the shell itself (14 14
released, hot, from the vents on the cover of the shell itself (
- fi g. 1 on page 3).
- fi g. 1 on page 3).
For this mode, the caps of the vents at the base of the shell
For this mode, the caps of the vents at the base of the shell
must be removed and the environmental air must be able to
must be removed and the environmental air must be able to
easily enter (check if the fi replace is fi tted with a casing).
easily enter (check if the fi replace is fi tted with a casing).
• •
CIRCULATION BY FORCED VENTILATION
CIRCULATION BY FORCED VENTILATION
installation kit for the apparatus beneath the main body
installation kit for the apparatus beneath the main body
(fi gs. 11-12-13) (ONLY for versions SIDE 50x50 and SIDE
(fi gs. 11-12-13) (ONLY for versions SIDE 50x50 and SIDE
2) 2)
For
Forced circulation of hot air is obtained by using the special kit
ced circulation of hot air is obtained by using the special kit
code 738910 beneath the supporting frame.
code 738910 beneath the supporting frame.
The kit is composed of:
The kit is composed of:
- 800 m³/h fan
- 800 m³/h fan
- regulator
- regulator
- sensor
- sensor
To install, proceed as follows:
To install, proceed as follows:
- Take off the front part by removing the 4 screws (a - fi g.
- Take off the front part by removing the 4 screws (a - fi g.
11/12).
11/12).
- Connect the two connectors M and F (fi g. 11).
- Connect the two connectors M and F (fi g. 11).
- Remove one of the two pre-cut plugs located on the metal box
- Remove one of the two pre-cut plugs located on the metal box
(fi g. 11/12) to create a passage for the lead from the fan to the
(fi g. 11/12) to create a passage for the lead from the fan to the
regulator.
regulator.
- Replace the front part of the box with the 4 screws.
- Replace the front part of the box with the 4 screws.
- Extend the electric wire from the regulator (r - fi g. 11) to an
- Extend the electric wire from the regulator (r - fi g. 11) to an
electric socket.
electric socket.
- The wire with the sensor (s - fi g. 11) must be extended to one
- The wire with the sensor (s - fi g. 11) must be extended to one
of the hot air exit vents (b - fi g. 12) normally positioned on the
of the hot air exit vents (b - fi g. 12) normally positioned on the
mantel.
mantel.
- The sensor must be fi xed into the hole of the vent.
- The sensor must be fi xed into the hole of the vent.
check that the sensor wire does not interfere with the sliding
check that the sensor wire does not interfere with the sliding
door.
door.
- Afterwards, insert the plug into the 220 V mains socket.
- Afterwards, insert the plug into the 220 V mains socket.
N.B.: the skirting board of the casing must be removable to al-
N.B.: the skirting board of the casing must be removable to al-
low the air box to be inspected.
low the air box to be inspected.
CIRCULATION OF HOT AIR
- fi g. 1
220 V mains
Fig. 11
Fig. 12
sensor
regulator
220 V mains
Fig. 13
- 23
-
connection
grille
sensor
fan
regulator
clamp
vent (b)
fan

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Side 50x50Side 2Side 3

Tabla de contenido