SETTING THE FIRST REMOTE CONTROL

This operation can only be performed when the motor is new, or after a total delete
of the memory.
During this step, power up only one motor at time!
T1: First remote control to be set
+
A
B
T1
Every time you connect the power supply to the motor, you have 3 hours to
store the first remote control. After this time, the ability to store the remote
control is disabled. To reset the timer of the function you have to disconnect
and reconnect the power supply to the motor.

ADJUSTMENT OF THE LIMIT SWITCHES

TM2 ERX tubular motors have an electronic limit switch system with an encoder.
This system ensures great reliability and precision in keeping the positions. Limit
switch regulation is performed simply with the remote control. During setting, the
motor moves only as long as the up or down button is pressed, stopping when the
button is released. At the end of setting, press either the up or down button briefly
to move the motor.
The adjustments of the limit switches can be done in different modes depending on
whether the rolling shutter is equipped with lockdown hangers or physical stops.
In this mode it doesn't matter whether or not the rolling shutter has got physical
stops in the opening position and the lockdown hangers in the closing position.
It is possible to choose whether to set the upper limit or the lower limit first. The
correct rotation direction will only be identified after the first position is set so it is
sometimes necessary to use the "up" or "down" button.
TM2 ERX
B
AUTOMATIC DISABLING OF THE FIRST
REMOTE CONTROL SETTING FUNCTION
SETTING IN MODE 1 (MANUAL)
T1
29
B
T1 (2 sec)
A4518_6G41_Rev.A