USER'S MANUAL. PRODIG-3

6 DESCRIPTION OF THE INPUTS AND OUTPUTS

6.1

RF input

The RF input is through the RF
signal level should never exceed 130 dBµV.
6.2

RS-232C serial port

The PRODIG-3 incorporates an RS-232C serial port for diagnosis, setup and
calibration processes. The signals in this connector are described in Table 4.
PIN No.
SIGNAL
1
Carrier detect
2
Data Receive (RxD)
3
Data Transmit (TxD)
4
Data Terminal Ready (DTR)
5
Ground (GND)
6
Data Set Ready (DSR)
7
Request to Send (RTS)
8
Clear to Send (CTS)
9
Ring Indicator