adjustable automatic closing time is
automatically interrupted by the activation
of any safety system, and is deactivated
after a STOP command or in case of power
failure;
- Obstacle detection: When the motor is
stopped (gate is closed, open or half-open
after an emergency stop command), the
transmitter and the control pushbutton will
be deactivated if an obstacle is detected by
one of the safety devices (for example, the
photocells);
- Hammer movement: This feature makes it
easy for the lock to release (the door wings
momentarily press against the closure
stops when the open command is given,
which facilitates release of the electric
lock);
- Cycle lamp. The lamp which lights the
manoeuvring zone: it remains lit from the
moment the doors begin to open until they
are completely closed (including the time
required for the automatic closure). In case
automatic closure is not enabled, the lamp
remains lit only during movement (10-E3).
Select it using the jumpers (see p. 20);
- The panel is enabled at the command for
ATI gearmotors or at the command for
FERNI and FROG gearmotors, which can
be selected with the 4-way dip-switch (see
p. 23).
- "Operator present" function: Gate
operates only when the pushbutton is held
down (the radio remote control system is
deactivated);
- Flashing light activated before opening
and closing cycle begins;
- Type of command:
- «open-stop-close-stop» for pushbutton
and radio transmitter;
- «open-close-reverse» for pushbutton and
radio transmitter;
- «open only» for radio transmitter.
Adjustments
- REG/FINE trimmer = Fine adjustment of
amperometric sensitivity during motor
operation
- Trimmer SENS/VEL = Adjustment of
amperometric sensitivity during operating:
min/max;
- Trimmer SENS/RALL = Adjustment of
amperometric sensitivity during slowdown:
min/max;
- Trimmer TCA = Adjustment of automatic
closing time: 2" to 120";
- Trimmer TR2M = Delay on closing cycle -
motor 2: 1" to 15";
- Trimmer TL = Adjustment of operating
time: 13" to 120";
- Faston connectors on the circuit card are
used to select normal operating and
slowdown speeds;
Caution! Shut off the mains power
and disconnect the batteries before
servicing the inside of the unit.