Sub-menu/parameter
Current output
4-20 mA
Iout at alarm
21 mA
Reset
counter
System zero
2.0000 Hz
Flow indication
Standard
D184B112U04
FXL5000 (Miniflow)
Type of input
tabular
Current output
4-20 mA
Current output
0-20 mA
tabular
Reset
counter
Yes –> Enter
tabular
System zero
manual
System zero
automatic
Comment
0-20 μA or 4-20 μA can be selected
Default value for current output is "4−20 mA"
Exit the sub-menu using
#
Confirm the new value using
Current output during fault
With 4−20 μA, the following status can be selected for the current
output: 0 mA; 3.6 mA; 21 mA
With 0−20 μA, the following status can be selected for the current
output: 0 mA; 21 mA
Default value for Iout with alarm is "21 mA"
The counter in the display functions as a differential counter, i.e.
inlet and outlet volumes are displayed on a counter.
Reset counter to zero using
Exit sub-menu using
#
Manual input of zero
Valve must be closed. Pipe must be filled completely. Fluid must
be at standstill. The autom. zero adjustment is started using
ENTER. The limit for the zero is 50 Hz. If the value is outside this
limit, there is no zero adjustment.
Exit the sub-menu using
#
Standard/Opposite
Definition of the forward flow direction for an installed instrument.
Standard = no change
Opposite = reversed indication