Model No.
A
WFL111
3.91
(99,3)
WFL112
3.91
(99,3)
Model No.
I
WFL111
1.08
(27,4)
WFL112
1.08
(27,4)
Model No.
Q
WFL111
.94
(23,9)
WFL112
.94
(23,9)
Model No.
A
WSL111
3.35
(82,6)
WSL112
3.35
(82,6)
Model No.
I
WSL111
.94
(23,9)
WSL112
.94
(23,9)
Model No.
Q
WSL111
.94
(23,9)
WSL112
.94
(23,9)
WARNING The fixture manifold must be
capable of withstanding a hydraulic 5000 psi
(350 bar) working pressure.
3. If making hydraulic connections to the side port,
remove the port plug and connect the hydraulic
line using appropriate fittings. All hoses, lines, and
fittings must be rated at 5000 psi (350 bar)
minimum.
A - spring force adjustment screw
B - portscrew (must be removed for manifold
mounting
C - O-ring (for manifold mounting)
D - breather vent tube
B
C
3.53
#4 SAE
(89,7)
3.53
.25-19
(89,7)
BSPP
J
K
3.35
.18
(85,1)
(4,6)
3.35
.18
(85,1)
(4,6)
R
S
1.62
Ø2.38
(41,1)
(Ø60,5)
1.62
Ø2.38
(41,1)
(Ø60,5)
B
C
2.97
#4 SAE
(75,4)
2.97
.25-19
(75,4)
BSPP
J
K
2.79
.18
(70,9)
(4,6)
2.79
.18
(70,9)
(4,6)
R
S
1.62
02.38
(41,1)
(60,5)
1.62
02.38
(41,1)
(60,5)
Figure 2
D
E
.25
.56
(6,4)
(14,2)
.25
.56
(6,4)
(14,2)
L
M
Ø.629
1.375-18
(Ø16,0)
UNEF
Ø.629
M35x1,5
(Ø16,0)
6G
T
U
.75
1.50
(19,1)
(38,1)
.75
1.50
(19,1)
(38,1)
D
E
.25
.44
(6,4
(11,2)
.25
.44
(6,4)
(11,2)
L
M
Ø.629
1.375-18
(Ø16,0)
UNEF
Ø.629
M35x1,5
(Ø16,0)
6G
T
U
.75
1.50
(19,1)
(38,1)
.75
1.50
(19,1)
(38,1)
4. The hydraulic power pump should not exceed
5000 psi (350 bar) maximum. Power pumps must
be large enough to provide a usable oil supply for
the work supports, hoses, clamps, and all items in
the system. Refer to Table 1 for maximum applied
loads vs. operating pressure.
5. When there is a risk of machining coolants,
debris, and chips entering the cylinder via the
breather vent (see Figure 2), plumb into the vent
port with a line which runs to an area protected
from chips, coolant, etc.
5.1 For Spring Advanced Work Supports Only:
If machining coolant and debris will create a problem of
entering the work support, install the work support as
an air spring type. This will blow air through the wiper
and help prevent coolant and debris from entering the
work support.
1. Remove the contact bolt from within the work
support plunger together with the spring inside.
2. After removing the spring, replace the contact bolt
utilizing Loctite 242 to seal the threads.
3. Connect the air breather tube to the air vent port.
By providing an adjustable zero to 5 psi (0,35 bar)
air supply, the work support will now become an
"air spring" loaded work support.
4. Increase or decrease the contact force of the
plunger against the workpiece by adjusting the
air supply pressure.
NOTE: To prevent the part from lifting, do not exceed 5
psi (0,35) bar. To provide an air advanced type of work
support, install an air line (described above) and add a
3
F
G
.57
2.02
(14,5)
(51,3)
.57
2.02
(14,5)
(51,3)
N
O
M10x1,5
.38
6G
(9,7)
M10x1,5
.38
6G
(9,7)
Dimensions inches (mm)
F
G
.57
1.60
(14,5)
(40,6)
.57
1.60
(14,5)
(40,6)
N
O
M10x1.5
.38
6G
(9,7)
M10x1,5)
.38
6G
(9,7)
Dimensions inches (mm)
H
.70
(17.8)
.70
(17.8)
P
Ø.284
(Ø7,21)
Ø.284
(Ø7,21)
H
.39
(9,9)
.39
(9,9)
P
Ø.284
(Ø7,21)
Ø.284
(Ø7,21)

Publicidad