11.3
Packings
1. Remove inlet valve housing in accordance with the steps in
Chapter 11.2, Page 14.
2. It is not necessary to remove the outlet valve.
3. Unscrew both cylinder head screws (Fig. 12, Item 1) from
the pump manifold (2) with a 3/8 inch hexagon socket head
wrench.
4. Slide the pump manifold (2) and piston (3) forward until the
piston is out of the T-slot (10) on the slider assembly (5).
5. Push piston (3) downward out of the pump manifold (2).
6. Unscrew retainer nut (6) from the pump manifold (2) and
remove piston guide (7).
7. Remove upper packing (8) and lower packing (9) from the
pump manifold (2).
Performance Series 650e
GB
8
10
9
11
12
7
10
8. Clean pump manifold (2).
9. Lubricate upper packing (8) and lower packing (9) with
machine grease.
10. Insert upper packing (Fig. 13) with O-ring (1) and protruding
lip (2) downward.
1
2
11. Insert lower packings (Fig. 13) with O-ring (1) and protruding
lip (2) upward.
2
1
12. Insert piston guide (Fig. 12, Item 7) into the retainer nut (6).
Screw retainer nut (6) into the pump manifold (2) and tighten
by hand.
13. Push installation tool (included with the replacement
packings) for the piston (3) from above onto the piston.
14. Lubricate installation tool and piston (3) with machine grease.
15. Guide piston (3) through the lower packings (9) into the pump
manifold (2) from below. Using a rubber mallet, lightly tap the
piston (3) from below until it can be seen above the pump
manifold.
16. Remove installation tool from piston (3).
17. Carefully tighten retainer nut (6) with adjusting wrench.
15
Repairs at the unit
5
6
7
8
4
2
1
9
3