FACTORY SETTINGS

This unit is equipped with a Boost speed function . Boost can be activated by means an external dedicated switch (not
supplied, Fig.11
)
4
AUTO (V.min
m3/h
Supply Channel
Exhaust Channel
Supply Channel
Exhaust Channel

ELECTRICAL CONNECTIONS

WARNING: THIS APPLICATION MUST BE EARTHED. ALL WIRING MUST CONFORM TO LEGAL REQUIREMENTS
AND STANDARDS IN THE COUNTRY WHERE THE APPLIANCE IS USED
The unit is suitable for a 230V, 50Hz single phase supply fused at 3A.
The unit needs a mains flexible cord. Connect the cord to the terminal block and exit through a grommet and cable clamp.
NOTE: in order to permanently disable the Boost function, don't connect any electrical wire to the "SL" termination (fig 11 SL)
A fused spur, or triple pole switch having a minimum contact separation of 3.0mm, must be used to provide isolation for the
unit. The unit is designed to be wired directly to the mains supply through a fused spur isolator which allows it to run
continuously.
ELECTRICAL WIRING OPTIONS
The unit is normally designed to ventilate continuously to give ~ 20 m
A facility is included which boosts the duty as required. The boost is achieved by:- Connecting black wire (from the mains
lead) to a switch (
in fig.11) wich is generally used to activare the boost mode in the UK market.
NOTE: For informations about installation, configuration, wiring and utilization see respective HRI MINI CB (fig. 10b)
optional command box Installation manual.

FAN PERFORMANCE GRAPH

9
Remote control Knob position
1 (V.med.)
.)
m3/h
(% Max flow rate)
(% Max flow rate)
46
20
(25%)
46
20
(25%)
2 (V.max.)
m3/h
(% Max flow rate)
72
(35%)
(60%)
72
(35%)
(60%)
86
(80%)
86
(80%)
3
/h supply and intermittent exhaust boost (~86 m
BOOST (Switch Live)
BY-PASS
m3/h
(% Max flow rate)
72
(60%)
20
(25%)
Fig.11
4
OFF
ON
3
/h).
33